NYC 9/11 Public Portal Document
Pace Analytical Services, Inc.
1700 Elm Street - Suite 200
Minneapolis, MN 55414
^ace Analytical___________
Method 8290 Laboratory Control Spike Results
Tel: 612-607-1700
Fax: 612- 607-6444
/ Client - ATC
Lab Sample ID SPIKE-1607
Filename F20429A_02 Matrix WIPE
Total Amount Extracted 1 m2 Dilution NA
ICAL Date 04/12/2002 Extracted 04/24/2002
CCal Filename(s) F20429A_01 & F20429A_15 Analyzed 04/29/2002 11:04
Method Blank ID BLANK-1592 Injected By BAL
Native Qs Qm % Internal ng's Percent
Isomers (ng) (ng) Standards Added Recovery
Rec.
2,3,7,8-TCDF 0.20 0.18 90 2,3,7,8-TCDF-13C 2.00 74
2,3,7,8-TCDD-13C 2.00 77
1,2,3,7,8-PeCDF-13C 2.00 85
2,3,7,8-TCDD 0.20 0.17 87 2,3,4,7,8-PeCDF-13C 2.00 79
1,2,3,7,8-PeCDD-13C 2.00 83
1,2,3,4,7,8-HxCDF-13C 2.00 96
1,2,3,7,8-PeCDF 1.00 0.90 90 1,2,3,6,7,8-HxCDF-13C 2.00 74
2,3,4,7,8-PeCDF 1.00 0.91 91 2,3,4,6,7,8-HxCDF-13C 2.00 81
1,2,3,7,8,9-HxCDF-13C 2.00 81
1,2,3,4,7,8-HxCDD-13C 2.00 95
1,2,3,7,8-PeCDD 1.00 0.93 93 1,2,3,6,7.8-HxCDD-13C 2.00 85
1,2,3,4,6,7,8-HpCDF-13C 2.00 85
1,2,3,4,7,8,9-HpCDF-13C 2.00 77
1,2,3,4,7,8-HxCDF 1.00 0.86 86 1,2,3,4,6,7.8-HpCDD-13C 2.00 94
1,2,3,6,7,8-HxCDF 1.00 0.93 93 OCDD-13C 4.00 67
2,3,4,6,7,8-HxCDF 1.00 0.91 91
1,2,3,7,8,9-HxCDF 1.00 0.90 90 1,2,3,4-TCDD-13C 2.00 NA
1,2,3,7,8,9-HxCDD-13C 2.00 NA
1,2,3,4,7,8-HxCDD 1.00 0.92 92 2,3,7.8-TCDD-37CI4 0.20 91
1,2,3,6,7,8-HxCDD 1.00 0.95 95
1,2,3,7,8,9-HxCDD 1.00 0.92 92
1,2,3,4,6,7,8-HpCDF 1.00 0.97 97
1,2,3,4,7,8,9-HpCDF 1.00 0.92 92
1,2,3,4,6,7,8-HpCDD 1.00 0.91 91
□CDF 2.00 1.55 77
OCDD 2.00 2.01 101
Qs = Quantity Spiked
Qm = Quantity Measured
Tec. = Recovery (Expressed as Percent)
? = Recovery outside of targrst range
X = Background subtracted value
Nn = Value obtained from additional analysis
NA = Not Applicable
’ = See Discussion Report No.... 02-1056375
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc.
CONFIDENTIAL, CITY_21MC100_003431956
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008