^ace Analytical__________ Method 8290 Analysis Results
Tel: 612-607-1700
FaxL612-_6Q7-6444
Client - ATC
Client's Sample ID ATC-0412-M894-DX2
Lab Sample ID 103468393
Filename F20430B_08
Injected By BAL
Total Amount Extracted 1 m2 Matrix WIPE
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 04/12/2002
ICAL Date 04/12/2002 Received 04/16/2002
CCal Filename{s) F20430A 13 & F20430B_16 Extracted 04/24/2002
Method Blank ID BLANK-1592 Analyzed 05/01/2002 00:56
Native Cone EMPC LRL internal ng's Percent
Isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
2,3,7,8-TCDF 0.0055 0.0020 J 2,3,7,8-TCDF-13C 2.00 78
Total TCDF 0.1700 0.0020 2,3,7,8-TCDD-13C 2.00 76
1,2.3,7,8-PeCDF-13C 2.00 74
2,3,7,8-TCDD ND 0.0037 A 2,3,4,7,8-PeCDF-13C 2.00 69
Total TCDD 0.4300 0.0020 B 1,2,3.7,8-PeCDD-13C 2.00 71
1,2,3,4,7,8-HxCDF-13C 2.00 107
1,2,3,7,8-PeCDF ND 0.0100 1,2,3,6,7,8-HxCDF-13C 2.00 62
2,3,4,7,8-PeCDF ND 0.0100 2,3,4,6,7,8-HxCDF-13C 2.00 85
Total PeCDF 0.0310 0.0100 J 1,2,3,7,8,9-HxCDF-13C 2.00 71
1,2,3,4,7,8-HxCDD-13C 2.00 102
1,2,3,7,8-PeCDD ND 0.0100 1,2,3,6,7,8-HxCDD-13C 2.00 87
Total PeCDD 0.1100 0.0100 1,2.3,4,6,7,8-HpCDF-13C 2.00 68
1,2,3,4,7,8,9-HpCDF-13C 2.00 53
1,2,3,4,7,8-HxCDF ND 0.0100 1,2,3,4,6,7,8-HpCDD-13C 2.00 69
1,2,3,6,7,8-HxCDF ND 0.0100 OCDD-13C 4.00 46
2.3,4,6,7,8-HxCDF ND 0.0100
1,2,3,7,8,9-HxCDF ND 0.0100 1,2,3,4-TCDD-13C 2.00 NA
Total HxCDF 0.0120 0.0100 J 1,2,3,7.8,9-HxCDD-13C 2.00 NA
1,2,3,4,7,8-HxCDD ND 0.0100 2.3,7.8-TCDD-37CI4 0.20 86
1,2,3,6,7,8-HxCDD ND 0.0100
1,2,3,7,8,9-HxCDD ND 0.0100
Total HxGDD 0.0330 0.0100 J
1,2,3,4,6,7,8-HpCDF- 0.0130 0.0100 J Total 2,3,7,8-TCDD
1,2,3,4,7,8,9-HpCDF- ND 0.0100 Equivalence; 0.0011 ng/m2
Total HpCDF 0.0130 0.0100 J (Using ITE Factors)
1,2,3,4,6,7,8-HpCDD 0.0230 0.0100 J
Total HpCDD 0.0350 0.0100 J
OCDF 0.0310 0.0200 J
OCDD 0.1600 0.0200
LRL = Lower Reporting Limit
Cone = Concentration (Totals include 2,3,7,8-substituted isomers) I = Interference
EMPC = Estimated Maximum Possible Concentration E = PCDE Interference
A = Detection Limit based on signal-to-noise measurement S = Saturated signal
J = Concentration detected is below the calibration range ND = Not Detected
B = Less than 10 times highei' than method blank level NA = Not Applicable
P = Recovery outside of target range NC = Not Calculated
Nn = Value obtained from additional analysis * = See Discussion
Report No.... 02-1056375
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc.
CONFIDENTIAL, CITY_21MC100_003431954
SUBJECT TO PROTECTIVE ORDER NO, 2, SEPT, 2008
NYC-WTC_000240200
OCR can misread numbers and units. Confirm readings against the page image before using them.