NYC 9/11 Public Portal Document
ENVIRONMENTAL TESTING
PSC AMALVTSCAL INDUSTRIAL HYGIENE
■EPAAVLA? 101262-0 • NY DOHAIEtAC 10903 •NJ 0£P PAC20
•AIHA ACCREDITATION NO. 100439 •PAOEP 08-353 •CT DPHPH-0238
•NC DENR 699
Analytical Results
for
ATC Associates
WorkOrder: R02050497
Client Reference; 19125-0290
Analyte Concentration Limit of Test Date Analyzed
Detection Method /Analyst
(ugj : (mg/m’) ; (ppm) (ug)
Client ID: ATC-05I0-MS94-M5 LablD:-05A Date Sampled: 5/10/02 Matrix: Filter Air VoL(L): NA
Aluminuri <1.00 1 N7300 MCE 05722/2002 AJB
Cadmium ’ <0.200 0.2 N7300 MCE 05/22/2002 AJB
Chromium 0.754 0.2 N7300 MCE 05/22/2002 AJB
Cobalt <0.100 0.1 N730O MCE 05/22/2002 AJB
Copper <0.200 0.2 N730O MCE 05/22/2002 AJB
Iron <2.00 2 N7300 MCE 05/22/2002 AJB
Lead <0.300 0,3 N7300 MCE 05/22/2002 AJB
Magnesium <1.30 1.3 N7300 MCE 05/22/2002 AJB
Manganese <0.300 0.3 N7300 MCE 05/22/2002 /AJB
Molybdenum <1.00 1 N7300 MCE 05/22/2002 AJB
Nickel <0.200 0.2 N7300 MCE 05/22/2002 AJB
Zinc <0.500 0.5 N7300 MCE 05/22/2002 AJB
Client ID: ATC-0510-M894-M6 Lab ID: -0<5A Date Sampled: 5/10/02 Matrix: Filter Air Vol.(L): NA
Aluminum <1.00 1 N7300 MCE 05/22/2002 AJB
Cadmium <0.200 0.2 N7300 MCE 05/22/2002 AJB
Chromium 0.423 0.2 N7300 MCE 05/22/2002 AJB
Cobalt <0.100 0.1 N73O0 MCE 05/22/2002 AJB
Copper <0.200 0.2 N7300 MCE 05/22/2002 AJB
Iron <2.00 2 N7300 MCE 05/22/2002 AJB
Lead <0.300 0.3 N730O MCE 05/22/2002 AJB
Magnesium <1.30 1.3 N7300 MCE 05/22/2002 AJB
Manganese <0.300 0.3 N7300 MCE 05/22/2002 AJB
Molybdenum <1.00 1 N7300 MCE 05/22/2002 AJB
Nickel <0.200 0.2 N7300 MCE 05/22/2002 AJB
Zinc <0.500 0.5 N7300 MCE 05/22'2002 AJB
(a) Analysis indicates possible breakthrough; back section result is greater than 0% of the front section result.
General Notes:
<; Less than the indicated limit of detection (LOD).
Information not available or not applicable.
Back sections were checked and showed no significant breakthrough.
u ; 0
Page 3 of 3
CONFIDENTIAL, CITY_21MC100_003431676
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000240031
OCR can misread numbers and units. Confirm readings against the page image before using them.