NYC 9/11 Public Portal Document
Mr. Bernard P. Orlan June 25, 2002
Respirable Particulate Monitoring Page 2
Various Locations/Manhattan ATC Project No. 15-19125-0314
»
TARGET GUIDELINES FOR AIR QUALITY PARAMETERS EVALUATED*
Respirable 65 micrograms per cubic
Particulates meter of air (jig/m^) 24 hour USEPA NPAAQS
(PM2.5) average
Respirable USEPA recommendation
Particulates 40 Jig/iiU 24 hour average for children/sensitive
(PM2.5) individuals
USEPA = United States Environmental Protection Agency
NPAAQS = National Primary Ambient-/br Quality Standard
REAL-TIME SAMPLING RESULTS
Thirty-one (31) indoor and thirty-four (34) outdoor respirable particulates
measurements* were collected from twenty-nine (29) school locations in
Manhattan, ranging from West 1 l^h Street to East 33'‘> Street. The
measurements were made from 5:47 A.M. to 4:33 P.M. The lAQ field report
forms are provided as the Attachment.
The outdoor PM2.5 concentrations ranged from 114 jig/m^ to 183 jig/m3 with an
average of 156 jig/m3. The indoor concentrations ranged from 58 jig/m3 to 164
jig/m3 with an average of 134 jig/mv Thirty (30) of the indoor and all thirty-
four (34) of the outdoor readings were above the NPAAQS of 65 jig/m3 24-hour
average concentration of particulate matter 2.5 micrometers or less in
aerodynamic diameter. All of the indoor and outdoor readings were above the
USEPA recommended guideline for children and sensitive individuals of 40
|ig/ni3.
These measurements were instantaneous readings, the NPAAQS and the
recommendation for children are 24-hour averages.
CONCLUSION
Based on our measurements the indoor concentrations ranged from 58 pg/nU
to 164 pg/m’ with an average of 134 jxg/m^. Thirty (30) of the indoor and all
thirty-four (34) of the outdoor readings were above the NPAAQS of 65 jig/m^
24-hour average concentration of particulate matter 2.5 micrometers or less in
aerodynamic diameter. All of the indoor and outdoor readings were above the
USEPA recommended guideline for children and sensitive individuals of 40
pg/mU
It is our pleasure to provide these air quality consultative services to the New
York City Board of Education. If you have any questions about this report,
please call (212) 353-8280, extension 212 or 211.
Sincerely,
ATC ASSOCIATES INC.
■/
/yViannis Efsta^iou
Senior Project Manager
Attachment
CONFIDENTIAL, CITY_21MC100_003422945
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000239933
OCR can misread numbers and units. Confirm readings against the page image before using them.