NYC 9/11 Public Portal Document
Mr. Bernard P Orlan September 9, 2002
Air Sampling for Hydrocarbons Page 2
P S 1 (Manhattan)__________ ATCProiectNo 15-19125-0340
The sampling locations were as follows
r‘ Floor Main Lobby, 2“* Floor Hallway by Room 213 and 4“" Floor Hallway by Room
403
Results
The only hydrocarbons in the analyte panel detected m the samples were acetone and Xylene.
Acetone was found in the sample collected from the 4* floor hallway by room 403 and Xylene
was found m the sample collected from the main lobby The concentrations are shown in the
table.
ACETONE CONCENTRATIONS
March 13, 2002
LjOCAWK’t acetone
' S2VMPLENO.
Hallway by Room 403 0.088 BDL**
VOC3__________
Main Lobby BDL 0.18
VOCl
* parts per million
** Below Detection Limit
Acetone is a common solvent in a variety of industrial processes and is the principal component
nail polish remover. It has occasionally been detected m indoor samples, however a specific
source has not been identified in this case
Xylene is another solvent frequently found m paints and coatings. Its presence m the Mam
Lobby sample cannot be linked to any specific activity in the building, it may be a trace
contaminant from outdoors.
No other HCs in the panel were present in the samples above the limits of detection for the
analyses
ATC appreciates the opportunity to provide this air quality service to the DOE. Please call (212)
353-8280 extension 370 or 212 if you have any questions.
Sincerely,
ATC Associates, Inc.
Reviewed by
Tenzin FJarri^al James R. Cohn, CIH, CSP
Industrial Hygienist Regional Manager