NYC 9/11 Public Portal Document
Pace Analytical Services Inc
1700 Elm Street Suite 200
Minneapolis MN 55414
Analytical' Method 8290 Analysis Results
Tel 612 607 1700
Fax 612 607 6444
Client ATC ASSOCIATES
Clients Sample ID ATC 0822 131M DX2
Lab Sample ID 103800397
Filename U20929B_10
Injected By BAL
Total Amount Extracted 1 00 m2 Matrix WIPE
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 08/22/2002
I CAL Date 08/06/2002 Received 08/24/2002
CCal Filename(s) U20929B_01 & U20929B_17 Extracted 09/17/2002
Method Blank ID BLANK 2163 Analyzed 09/30/2002 08 06
Native Cone EMPC LRL Internal ng s Percent
Isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
2 3 7 8 TCDF ND 0 00200 23 7 8 TCDF 13C 2 00 35 P
Total TCDF 0 0021 0 00200 J 2 3 78 TCDD 13C 2 00 35 P
1 2378 PeCDF 13C 2 00 34 P
2 3 7 8 TCDD ND 0 00200 23478 PeCDF 13C 2 00 33 P
Total TCDD 0 0056 0 00200 BJ 1 237 8 PeCDD 13C 2 00 33 P
1 234 78 HxCDF 13C 2 00 44
1 2 3 7 8 PeCDF ND 0 01000 1 2 36 78 HxCDF 13C 2 00 38 P
2 3 4 7 8 PeCDF ND 0 01000 234 6 78 HxCDF 13C 2 00 39 P
Total PeCDF ND 0 01000 1 23789 HxCDF 13C 2 00 36 P
1 2 3478 HxCDD 13C 2 00 55
1 2 3 7 8 PeCDD ND 0 01000 1 23678 HxCDD 13C 2 00 35 P
Total PeCDD ND 0 01000 1 234678 HpCDF 13C 2 00 32 P
1 2 34 789 HpCDF 13C 2 00 29 P
1 2 3 4 7 8 HxCDF ND 0 01000 1 2 34678 HpCDD 13C 2 00 36 P
1 2 3 6 7 8 HxCDF ND 0 01000 OCDD 13C 4 00 29 P
2 3 4 6 7 8 HxCDF ND 0 01000
1 2 3 7 8 9 HxCDF ND 0 01000 1 2 34 TCDD 13C 2 00 NA
Total HxCDF ND 0 01000 1 2 37 89 HxCDD 13C 2 00 NA
1 2 3 4 7 8 HxCDD ND 0 01000 2 3 7 8 TCDD 37CI4 0 20 37
1 2 3 6 7 8 HxCDD ND 0 01000
1 2 3 7 8 9 HxCDD ND 0 01000
Total HxCDD ND 0 01000
1 2 3 4 6 7 8 HpCDF ND 0 01000 Total 2 3 7 8 TCDD
1 2 3 4 7 8 9 HpCDF ND 0 01000 Equivalence 0 00059 ng/m2
Total HpCDF ND 0 01000 (Using ITE Factors)
1 2 3 4 6 7 8 HpCDD 0 0270 0 01000 J
Total HpCDD 0 0530 0 01000 J
OCDF ND 0 02000
OCDD 0 3200 0 02000
LRL = Lower Reporting Limit
Cone = Concentration (Totals include 2 3 7 8 substituted isomers) 1 = Interference
EMPC = Estimated Maximum Possible Concentration E = PCDE Interference
A = Detection Limit based on signal to noise measurement S = Saturated signal
J = Concentration detected is below the calibration range ND = Not Detected
B = Less than 10 times higher than method blank level NA = Not Applicable
P = Recovery outside of target range NC = Not Calculated
Nn = Value obtained from additional analysis = See Discussion
Report No 1061758
REPORT OF LABORATORY ANALYSIS
This report shall not bo reproduced except in full
without the written consent of Pace Analytical Services Inc
CONFIDENTIAL, CITY_21MC100_003430956
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000239540
OCR can misread numbers and units. Confirm readings against the page image before using them.