NYC 9/11 Public Portal Document
Pace Analytical Services, Inc.
1700 Elm Street - Suite 200
Minneapolis, MN 55414
TM
^ace Analytical_________
Analysis Method 8290 Results
Tel: 612-607-1700
Client - ATC ASSOCIATES
Client’s Sample ID ATC-0822-131M-DX3
Lab Sample ID 103800405
Filename U20929B_11
Injected By BAL
Total Amount Extracted 1.00 m2 Matrix WIPE
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 08/22/2002
ICAL Date 08/06/2002 Received 08/24/2002
CCal Filename(s) U20929B_01 &U20929B_17 Extracted 09/17/2002
Method Blank ID BLANK-2163 Analyzed 09/30/2002 08:55
Native Cone EMPC LRL Internal ng’s Percent
Isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
2,3,7,8-TCDF — 0.0022 0.00200 I 2,3,7,8-TCDF-13C 2.00 32 P
Total TCDF ND — 0.00200 2,3,7,8-TCDD-13C 2.00 31 P
1,2,3,7,8-PeCDF-13C 2.00 33 P
2,3,7,8-TCDD ND 0.00250 A 2,3,4,7,8-PeCDF-13C 2.00 33 P
Total TCDD 0.0085 0.00200 BJ 1,2,3,7,8-PeCDD-13C 2.00 33 P
1,2,3,4,7,8-HxCDF-13C 2.00 40
1,2,3,7,8-PeCDF ND 0.01000 1,2,3,6,7,8-HxCDF-13C 2.00 39 P
2,3,4.7,8-PeCDF ND 0.01000 2,3,4,6,7,8-HxCDF-13C 2.00 38 P
Total PeCDF ND 0.01000 1,2,3,7,8,9-HxCDF-13C 2.00 35 P
1,2,3,4,7,8-HxCDD-13C 2.00 48
1,2,3,7,8-PeCDD ND 0.01000 1,2,3,6,7,8-HxCDD-13C 2.00 37 P
Total PeCDD ND 0.01000 1,2,3,4,6,7,8-HpCDF-13C 2.00 35 P
1,2,3,4,7,8,9-HpCDF-13C 2.00 31 P
1,2,3,4,7,8-HxCDF ND 0.01000 1,2,3,4,6,7,8-HpCDD-13C 2.00 35 P
1,2,3,6,7,8-HxCDF ND 0.01000 OCDD-13C 4.00 28 P
2,3,4,6,7,8-HxCDF ND 0.01000
1,2,3,7,8,9-HxCDF ND 0.01000 1,2,3,4-TCDD-13C 2.00 NA
Total HxCDF ND 0.01000 1,2,3,7,8,9-HxCDD-13C 2.00 NA
1,2,3,4,7,8-HxCDD ND 0.01000 2,3.7,8-TCDD-37CI4 0.20 33
1,2,3,6,7,8-HxCDD ND 0.01000
1,2,3,7,8,9-HxCDD ND 0.01000
Total HxCDD ND 0.01000
1,2,3,4,6,7,8-HpCDF ND 0.01000 Total 2,3,7,8-TCDD
1,2,3,4,7,8,9-HpCDF ND 0.01000 Equivalence: 0.000040 ng/m2
Total HpCDF ND 0.01000 (Using ITE Factors)
1,2,3,4,6,7,8-HpCDD ND 0.01000
Total HpCDD ND 0.01000
OCDF ND 0.02000
OCDD 0.0400 0.02000 J
LRL = Lower Reporting Limit
Cone = Concentration (Totals include 2,3,7,8-substituted isomers) I = Interference
EMPC = Estimated Maximum Possible Concentration E = PCDE Interference
A = Detection Limit based on signal-to-noise measurement S = Saturated signal
J = Concentration detected is below the calibration range ND = Not Detected
B = Less than 10 times higher than method blank level NA = Not Applicable
P = Recovery outside of target range NC = Not Calculated
Nn = Value obtained from additional analysis * = See Discussion
Report No.... 1061758
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc.
CONFIDENTIAL, CITY_21MC100_003422541
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000239496
OCR can misread numbers and units. Confirm readings against the page image before using them.