Analytical Results
for
ATC Associates
VVorkOrder: R02080731
Client Reference: 19125-0346
Analyte Concentration Limit of Test Date Analyzed
Detection Method /Analyst
(ug) ; (mg/inO ; (ppm) (ug)
Client ID: ATC-0822-13IM-VOC4 Lab ID: -04A Date Sampled: S/22/02 Matrix; Charcoal AirVol.(L); NA
1,1,1 -T richloroethane <20 20 OSHA 7 08/26/2002 JLS
1.2-Dichloroethane <20 20 OSHA 7 08/26/2002 JLS
A Hydrocarbons, Total <20 20 OSHA 7 08/26/2002 JLS
Acetone <20 20 OSHA 7 08/26/2002 JLS
B Hydrocarbons, Total <20 20 OSHA 7 08/26/2002 JLS
Benzene <20 20 OSHA 7 08/26/2002 JLS
Chlorobenzene <20 20 OSHA 7 08/26/2002 JLS
Chloroform <20 20 OSHA 7 08/26/2002 JLS
Ethylbenzene <20 20 OSHA 7 08/26/2002 JLS
Hexane <20 20 OSHA 7 08/26/2002 JLS
Isopropylbenzene <20 20 OSHA 7 08/26/2002 JLS
Methylene Chloride <20 20 OSHA 7 08/26/2002 JLS
Pentane <20 20 OSHA 7 08/26/2002 JLS
Styrene <20 20 OSHA 7 06/26/2002 JLS
Tetrachloroethene <20 20 OSHA 7 08/26/2002 JLS
Toluene <20 20 OSHA 7 08/26/2002 JLS
Tri chloroethane <20 20 OSHA 7 08/26/2002 JLS
Xylenes, Total <20 20 OSHA 7 08/26/2002 JLS
(a) Analysis indicates possible breakthrough; back section result is greater than % of the front section result.
General Notes:
<; Less than the indicated limit of detection (LOD).
information not available or not applicable.
Back sections were checked and showed no significant breakthrough.
Page 4 oi'4