TEM Asbestos (air) Count Sheet
Client Name: NYC BOE Volume (liters): 1920
Lab Group #: 8828 Filter Type / Filter Area: MCE 385 mm^
Lab Sample #: 15 Grid Opening Size: 0.01124
Client Sample #: 15 Area Examined: 0.04496 mm-
GRID BOX: Magnification: 20,000
GRID ID: Accelerating Voltage: 100 KeV
Grid Openings: 4 Analysis Date: 9/10/02
Analysis Performed By:
MARK PEYSAKHOV
GO. Structure Structure Type Length ID of Structure Nor 7 EDS
No (Noradb
F B C M >=05 p >-5)j Chrys Amphibole Nonasb Ambig/ND
No Coord <5p Elemenis)
Struct = > 0.5p > 5:1 Aspect Ratio Grid acceptance:
V = Positive diffraction pattern properties conforming to <50% undissolved filter, overlapped or folded Totals
laboratory identification criteria observed <10% particulate coverage >50% coverage ate
least 20 unfolded or overiapped grid squares <5% F B C M >5p
v= EDS spectrum conforming to laboratory holes or opaque areas
• identification criteria observed Chrysotile
AMPHIBOLES ' Amphibole
F = Single Fiber Amosite
B = Bundle (<3 fibers <1 fiber diameter apart Crocirdolite Ambiguous
C. = Cluster (>3 Intersections) Anthophyllite ■ Non-Asbestos
i Tremolite
M = Malrix Non-Identified
Actinolite
NSO = No Structures Detected
CONFIDENTIAL, CITY_21MC1OO_OO3422361