NYC 9/11 Public Portal Document
104 East 25th St.. 10th Fl
New York. New York 10010
www.atc-enviro.com
212.353.8280
1 Fax 212.353.8306
•0 ASSOCIATES INC.
September 19, 2002
Mr. Bernard P. Orlan
Director, Environmental Health and Safety
New York City Departrnent of Education
28-11 Queens Plaza North
Long Island City, NY 11101
Re: Air Sampling for Metals
Murray Bergtraum High School (M520)
ATC Project No. 15-19125-0351
Dear Mr. Orlan:
ATC Associates Inc. (ATC) is pleased to provide this report of air sampling for metals in
airborne dust conducted on September 11, 2002, in the referenced school building. The
New York City Department of Education (DOE) requested this sampling to verify that
acceptable indoor air quality is being maintained.
Scope of work
ATC collected three (3) samples for metals at specified locations. Samples were
collected for a minimum of eight (8) hours using 37 mm mixed cellulose ester filters
connected to battery-powered sampling pumps at a flow rate of 2 liters per minute.
Pumps were calibrated before and after each sampling period. All samples were
collected inside the building. Two sample blanks were also submitted. The samples
were sent to PSC Analytical Services, Inc., an American Industrial Hygiene Association-
accredited laboratory in Reading, PA. Analysis was performed by NIOSH Method
7300M.
Each sample was analyzed for a panel of twelve (12) metals. The metals were: aluminum
(Al), cadmium (Cd), chromium (Cr), cobalt (Co), copper (Cu), iron (Fe), lead (Pb),
magnesium (Mg), manganese (Mn), molybdenum (Mo), nickel (Ni) and zinc (Zn). A
copy of the analytical laboratory report is attached.
Tenzin Namgyal, Industrial Hygienist and Sonny Ramlal, Environmental Technician of
ATC’s New York City office, collected the samples consistent with generally accepted
industrial hygiene practices. As with all such sampling, there were inherent limitations
created by constraints of time, operational and work practice variability, variations in air
contaminant concentrations and sampling and analytical accuracy. The results of the
sampling represent conditions found on the date the samples were collected.
CONFIDENTIAL, CITY_21MC100_003422329