NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 3 pages

PCDD/PCDF determination report, PS 126M, Oct 2002

Machine-extracted title · confidence 90%

Laboratory report from Pace Analytical detailing the determination of PCDD and PCDF levels in samples from PS 126M collected in October 2002.

NYC-WTC_000239013–000239015
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Pace Analytical Services, Ine. irm Elm Street, Suite 200 ’aceAnalyticar REPORT OF: CHEMICAL ANALYSES Minneapolis, MN 55414 Phone: 612.607.1700 www.pacBlabs.com Fax: 612.607.6444

PROJECT: PCDD/PCDF ANALYSES DATE; October 21, 2002 1 3 ISSUED TO: ATC Associates REPORT NO :02-l 062004 Attn: Mr. Jim Cohn 104 East 25th Street, 10th Floor New York, NY 10010

INTRODUCTION

This report presents .the results from the analyses performed on three samples that were submitted by a representative of ATC Associates. The samples were analyzed for the presence or absence of polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) using a modified version of \ 1 USEPA Method 8290.

SAMPLE IDENTIFICATION

Client ID Sample Type Date Received Pace ID ; ATC-0829-126M-DX1 Wipe 08/30/02 103818258 ATC-0829-126M-DX2 Wipe 08/30/02 103818266 ATC-0829-126M-DX3 Wipe 08/30/02 103818274

1 DISCUSSION ■ ■ ■ ■ ■

The recoveries of the isotopically-labeled PCDD/PCDF internal standards in the sample extracts ranged from 53-97%. All of the labeled internal standard recoveries obtained for this project were within the target range specified in Method 8290. Also, since the quantifications of the native 2,3,7,8-substituted Isomers were based on Isotope dilution, the data were automatically corrected for variation in recovery and accurate values were obtained.

A laboratory method blank was prepared and analyzed with the sample batch as part of our routine J quality control procedures. The results, found at the beginning of Appendix B, show the blank to be free of PCDDs and PCDFs at the reported detection limits. This indicates that the sample preparation procedures did not significantly Impact the results of the field sample determinations.

REPORT OF LABORATORY ANALYSIS This report Shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.

mdact CONFIDENTIAL, CITY_21MC100_003430847 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000239014

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000239014Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000309591

Pace Analytical multi-page report with NELAC-compliant results.

Similar indexed content

NYC-WTC_000309603

14-page lab report; NELAC-compliant analyses for project 19125-0340.

Similar indexed content

NYC-WTC_000238887

Cover page for a laboratory analysis report from Pace Analytical Services regarding environmental testing samples.

Similar indexed content

NYC-WTC_000175186

Cover page for a 17-page laboratory report regarding PCDD/PCDF analyses conducted by Pace Analytical for ATC Associates.

Similar indexed content

NYC-WTC_000309581

Laboratory analysis report for project 19125-0340, Pace Analytical.

Similar indexed content

Compare copies and versions →