NYC 9/11 Public Portal Document
Mar 25 02 12:24p PSC Rnalatical Services 6109219BB7 p. 1 1
r=sc: INDUSTRIAL HYGIENE
•EPA/NVLAP101252-0
•AIHAACCREDITATION NO. 100439
■NCDENR599
• m DOHWELAC 10903
■PADEP 06-353
ENVIRONMENTAL TESTING
■NJ DEP PA02C
• C' DPH PH-023B
ANALYTICAL SERVICES Analytical Results
for
ATC Associates
WorkOrder; R02030688
Client Reference: 19125-0246
Analyte Concentration Limit of Test Date Analyzed
Detection Method /Analyst
(ug) (mg/m’) ; (ppm) (ug)
Client ID: MI ATC-03I3-STY Matrix: Filter
(oVw Lab ID: -OSA Date Sampled; 3/13/02 Air Vol.(L): 960
Aluminum <1.00 <0.00104 1 N730O MCE 03/22/2002 AJS
Caomiuin <0.200 <0.000208 0.2 N7300 MCE 03/22/2002 AJB
Chromium - 0.345 0.000359 0.2 N7300 MCE 03/22/2002 AJB
Cobolt <0.100 <0.000104 0.1 N7300 MCE 03/22/2002 AJB
Copper <0.200 <0.000208 0.2 N7300 MCE 03/22/2002 AJB
Iron <2.00 <0.00208 2 N7300 MCE 03/22/2002 AJB
Lead 0.346 0.000360----- 0.3 N7300 MCE 03/22/2002 AJB
Magnesium <1.30 <0.00135 1.3 N7300 MCE 03/22/2002 AJB
Manganese <0.300 <0.000312 0.3 N73O0 MCE 03/22/2002 AJB
Molybdenum <1.00 <0.00104 1 N7300 MCE 03/22/2002 AJB
I ; Nickel <0.200 <0.000208 0.2 N7300 MCE 03/22/2002 AJB
fe
—Zinc 1.44 0.00150 0.5 N7300 MCE 03/22/2002 AJB
Client ID: M2 ATC-0313-STY Lab ID:-1OA Date Sampled: 3/13/02 Matrix: Filter Air Vol.(L); 960
Aium.nam <1.00 <0.00104 1 N7300 MCE 03/22/2002 AJB
Cadmium <0.200 <0.000208 0.2 N7300 MCE 03/22/2002 AJB
.____ 0.281 0.000292 0.2 N7300 MCE 03/22/2002 AJB
Cobalt <0,100 <0.000104 0.1 N730O MCE 03/22/2002 AJB
Copper <0.200 <0.000208 0.2 N7300 MCE 03/22/2002 AJB
—.—Iron 3.3S 0,00352^ 2 N7300 MCE 03/22/2002 AJS
Lead 0.304 0.000317------- 0.3 N7300 MCE 03/22/2002 AJB
Magnesium <1.30 <0.00135 1.3 N7300 MCE 03/22/2002 AJB
Manganese 0.468 0.000487------- 0.3 N7300 MCE 03/22/2002 AJB
Molybdenum <1.00 <0.00104 1 N73O0 MCE 03/22/2002 AJB
Nickel <0.200 <0.000208 0.2 N7300 MCE 03/22/2002 AJB
_---2inc 2.68 0.00279-------- 0.5 N7300 MCE 03/22/2002 AJB
t
Page 5 of?
CONFIDENTIAL, CITY_21MC100_003429350
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000238219
OCR can misread numbers and units. Confirm readings against the page image before using them.