NYC 9/11 Public Portal Document

Pace Analytical Services, tnc. 170D Elm Street, Suite 200 'ace Analytical' Minneapolis, MN 55414 Phone: 612.607.1700 www.pacelabs.com REPORT OF: CHEMICAL ANALYSES Fax: 612.607.6444

]' PROJECT- PCDD/PCDF Jl^NALYSES DATE: January 9, 2002

PAGE: 7 REPORT NO: 01-1052540

.1 RESULTS W / ■ ■ 1 The results from the analyses are presented in the following:

Appendix A - Documentation Appendix B - PCDD/PCDF Analysis Results

-- ■ DISCUSSION

o The recoveries of the isotopically-labeled PCDD/PCDF internal standards in the sample extracts - ranged from 56-125% and indicate a level of efficiency through the extraction and enrichment steps that is considered typical for this matrix. All of the internal standard recoveries for the field samples were within the target limits for this method. Also, since the quantifications of the native 2,3,7,8-substituted isomers were based on isotope dilution, the data were automatically corrected . for variation in recovery and accurate values were obtained.

A laboratory method blank was prepared and analyzed with the sample batch as part of our routine : J quality control procedures. The results, found at the beginning of Appendix B, show the blank to be i | free of PCDDs and PCDFs. This suggests that the sample processing steps did not impact the results of the analyses.

[ j A laboratory spike sample was also prepared with the sample batch by extracting a clean wipe that had been fortified with native standard materials. The results, found at the end of Appendix B, i show that the spiked native compounds were recovered at 108-115%. This indicates a high I degree of accuracy for these determinations.

3

REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in lull, without the written consent of Pace Analytical Services, Inc.

CONFIDENTIAL, SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008 CITY_21 MC100_014660300

NYC-WTC_000237155

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000237155Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

PCDD/PCDF lab analysis results, Jan 2002

NYC-WTC_000226877

Pace Analytical laboratory report detailing polychlorinated dibenzo-p-dioxin and dibenzofuran levels in samples from a NYC school.

Similar indexed content

NYC-WTC_000272110

Laboratory analysis report from Pace Analytical for a site sample related to the Education Department project.

Similar indexed content

Compare copies and versions →