NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 4 pages

Toxic organic compounds air sampling report, PS 89M, Jan 2002

Machine-extracted title · confidence 95%

Letter report from ATC Associates detailing toxic organic compound air sampling results for P.S. 89M conducted on January 11, 2002.

NYC-WTC_000237098–000237101
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Mr. Bernard P. Orlan January 21, 2002 Air Sampling for Toxic Organic Compounds Page 2 P. S. 89 (Manhattan^ ATC Project No. 15-19125-0297

TABLEI TOXIC ORGANIC COMPOUNDS IDENTIFIED (ppb*) IPLE 'LL K-2 jii

BA ID

BENZENE 0.95 0.51 0.49

ETHYLBENZENE 0.30 BDL** BDL

METHYLENE BDL 2.25 0.92 CHLORIDE

TOLUENE 1.38 0.61 0.62

XYLENES 0.90 0.26 0.28

* ppb = parts per billion ** BDL = Below Detection Limits

None of the other TOCs in the panel were detected in the samples. Specific sources for the TOCs detected indoors were not found. Ethylbenzene is used as a solvent for resins and in industrial syntheses. Compounds such as toluene, xylene and methylene chloride are components of paints and coatings that may have been used inside the school. No painting was in progress while the samples were being collected.- Methylene chloride is also used in degreasers and cleaners (e.g. graffiti removers). There is no historical TOC data from the school to establish if the materials found and their concentrations are unusual. The Environmental Protection Agency (EPA) has set screening level for benzene of 20 ppb. This is based on a continuous exposure for one year. The benzene level detected indoors was approximately 0.5 ppb, well below the EPA screening level.

Library Search Results

Each sample was subjected toi further volatile organic analysis and numerous Tentatively Identified Compounds (TICs) were found. Concentrations ranges were 37 to 18.9 nanograms indoors and 26 to 351 nanograms utdoors.

In the 2 indoor samples, sixteen (16) individual TICs were found. Four TICs were found in both samples, these were 2-methyl butane, hexane, decane and uncecane. With the exception of decane, these were also detected in the outdoor sample. 2-methyl butane was detected in the highest concentrations in all three samples than any other TIC. The TIC with the highest concentration indoors, that was not found outdoors, was 3-methyl nonane found in the 4*'* floor hallway. This sample (VOC-3) contained sixteen (16) TICs, the largest number of compounds.

CONFIDENTIAL, SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008 CITY_21 MC100_014660221

NYC-WTC_000237099

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000237099Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.