Table 2C
Asbestos Microvac (ASTM 5575)
Phase 3
New York City Law Department
100 Church Street
New York
* Sample ID ; ZD032903MV2O01 ZD032903MV2002 ZD032903IVIV2001 2D032903MV2002
Lab Sample ID : 4 5 1 2
Sample Date : 3/29/2003 3/29/2003 3/29/2003 3/29/2003
* Sample Type : Geometric Microvac Microvac Microvac Microvac
Floor; Mean 20 20 20 20
Inside window Inside window
Surface Type: convector convector Carpet Carpet
Location; South west office Center of south South west office Center of south
CONSTITUENTS
ASBESTOS (structures/cm^) 512 891 <891 <891 <891
* Post Cleaning Target = <10,000 str/crn
(structures per square centimeter) individual
sample and geometric mean of <1,000
str/cm^