Page image not rendered yet. The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text
OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Table 2
Ongoing Air Monitoring
New York City Law Department
100 Church Street
New York
Sample ID ; MD0401 MD0501 MD0601 MD00O1 MDFB01
Lab Sample ID; OSHA 1 2 3 4 5
Sample Date : Permissible 6/28/2002 6/28/2002 6/28/2002 6/28/2002 6/28/2002
Start Time: Exposure Limit 11:50 11:37 12:05 12:19
Sample Type : (PEL)mg/m^ Air Air Air Air Air
Floor: 4 5 6 Roof
Southeast
Location: Room 5-101 Library
Corner Field Blank
CONSTITUENTS
TOTAL METALS (mg/m’)
Aluminum <0.00574 U <0.00574 U <0.00565 U <0.00565 U <0.005 U
Antimony <0.00115 U <0.00115 U <0.00113 U <0.00113 U <0.001 U
Arsenic <0.000459 U <0.000459 U <0.000452 U <0.000452 U <0.0004 U
Barium <0.00574 U <0.00574 U <0.00565 U <0.00565 U <0.005 U
Beryllium <0.000230 U <0.000230 U <0.000226 U <0.000226 U <0.0002 U
Cadmium <0.000230 U <0.000230 U <0.000226 U <0.000226 U <0.0002 U
Calcium <0.0574 U <0.0574 U <0.0565 U <0.0565 U <0.05 U
Chromium 1 0.00176 0.00162 0.00174 0.00145 0.00088
Cobalt <0.000574 U <0.000574 U <0.000565 U <0.000565 U <0.0005 U
Copper <0.00115 U <0.00115 U <0.00113 U <0.00113 U <0.001 U
Iron <0.00574 U <0.00574 U <0.00565 U <0.00565 U <0.005 U
Lead <0.000574 U <0.000574 U <0.000565 U <0.000565 U <0.0005 U
Magnesium <0.0574 U <0.0574 U <0.0565 U <0.0565 U <0.05 U
Manganese <0.000861 U <0.00C8S1 U <0.000847 U <0.000847 U <0.00075 U
Nickel <0.000115 U <0.000115 U <0.000113 U <0.000113 U <0.0001 U
Potassium <0.0574 U <0.0574 U <0.0565 U <0.0565 U <0.05 U
Selenium <0.00115 U <0.00115 U <0.00113 U <0.00113 U <0.001 U
Silver <0.000574 U <0.000574 U <0.000565 U <0.000565 U <0.0005 U
Sodium <0.0574 U <0.0574 U <0.0565 U <0.0565 U <0.05 U
Thallium <0.000574 U <0.000574 U <0.000565 U <0.000565 U <0.0005 U
Vanadium <0.000574 U <0.000574 U <0.000565 U <0.000565 U <0.0005 U
Zinc <0.00115 U <0.00115 U <0.00113 U <0.00113 U <0.001 U
U = Analyzed for but Not Detected
O
O
O
1^
o
4^
cn
CD
me
Custamer-Focused Solutions
O
CT>
J
NYC-WTC_000235907
OCR can misread numbers and units. Confirm readings against the page image before using them.
NYC-WTC_000235907Source: NYC Law Department, mirrored locally