Carpet Air Sample Data Table, Jan-Feb 2002

Machine-extracted title · confidence 90%

Table of air samples taken from carpet surfaces at the NYC Law Department building between late January and early February 2002.

NYC-WTC_000235456–000235467
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Table 2 Air Samples - Carpet OSHA PEL New York City Law Department 100 Church Street New York

Sample ID: OSHA0502 OSHA0505 OSHA0506 OSHA0507 OSHAO508 OSHA0509 OSHA0570 OSHA0511 OSHA0512 OSHA0513 OSHA0514 OSHA0517 OSHA0518 OSHA0519 OSHA0520 OSHA0603 Lab Sample ID : 2 1 2 3 4 2 1 2 3 4 1 2 3 4 1 Sample Date ; 2/8/02 2/9/02 2/9/02 2/9/02 2/9/02 2/11/02 2/11/02 2/11/02 2/11/02 2/11/02 2/11/02 2/12/02 2/12/02 2/12/02 2/12/02 2/13/02 Start Time: 14:10 9:00 9:01 15:00 15:01 15:30 15:31 7:30 7:35 14:30 14:34 8:00 14:00 8:05 14:03 8:10 Sample Type: Air Air Air Air Air Air Air Air Air Air Air Air Air Air Air Air Floor:

Cesar Peter Ramon Pedro Anthony Pedro Anthony Pedro Anthony Miguel Miguel Name of Personnel; Mike Luna Rodriguez Grimaldi Antonio Daniel Reilly Paulino Lindsey Paulino Lindsey Paulino Lindsey Rynoso Rynoso Kyle Jones Kyle Jones Mike Green

ASBESTOS (fibers/cc) <0.004 <0.004 0.004 <0.004 <0.004 <0.030 <0.030 0.010 0.008 0.005 <0.004 0.041 0.013 0.017 0.005 0.016

TEM Quality Control

ASBESTOS (structures/mmO NQCS NQCS NQCS NQCS NQCS NQCS NQCS NQCS NQCS NQCS NOGS <10 NQCS NQCS NQCS NQCS

< Indicates less than the limit of quantification 70 8tructures/mm‘ s aHERA re-occupancy criteria for school children NQCS - No quality control sample taken (1) Analyst was unable to quantify fiber concentration because of overioading of particulate matter on the filter. (2) Moderate to heavy particulate matter is present on the fitter which may obscure some fibers causing results with a low bias.

Page 3 Of 12 TRC Customer-Focused Solutions

NYC-WTC_000235458

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000235458Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000235468

Table of air samples taken from carpet surfaces at the NYC Law Department building between late January and early February 2002.

Similar indexed content

NYC-WTC_000235444

Table of ambient air sample data collected at the NYC Law Department building between January and February 2002.

Similar indexed content

Compare copies and versions →