WTC residential sampling plan draft, Oct 2001

Machine-extracted title · confidence 95%

Draft environmental sampling protocol for residential areas near the World Trade Center developed by ATSDR/DHAC in October 2001.

NYC-WTC_000235065–000235077
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Py,ivia Pry.ce - wtc residential sampling plan oct15 1.doc Page 111

VIL Screening Levels/Data Interpretation: Screening levels will be developed for respirable crystalline silica and PM in air; and for asbestos in vacuum dust and outdoor surface dust samples.

Data will be evaluated by local, state and federal public health agencies. Evaluations will include: 1) Indoor sample results will be evaluated on a residence-by- residence basis (for the individual occupants) 2) All indoor data will be evaluated to determine the extent of public health implications for residents near the WTC 3) All outdoor data will be evaluated to determine the extent of public health implications for the general public living near the WTC 4) The relationship between materials found in indoor and outdoor samples will be evaluated.

If results of testing show contamination/materials present at levels of concern, efforts should be made to reduce these levels and to take steps that eliminate transporting them indoors (e.g,. reduce contaminant track in by removing or changing shoes prior to entering residence, use HEPA filters on HVAC systems, keep windows closed).

VIII. Interference from existing bldg materials: It is anticipated that some of the contaminants/materials found in this sampling effort will be un-related to the WTC event. Attempts will be made during sample collection to note other possible sources of contaminants (Section IX, Sample Description Needs).

To better determine if contaminants/materials found are within area background levels, approximately ten residential units outside of the concentric circle zones will be selected testing (indoor air and surface dust, outdoor air and surface dust).

11

CONFIDENTIAL, CITY_21MC100_003382616 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000235075

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000235075Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →