NYC 9/11 Public Portal Document
sample area
TEM Asbestos (dust) Count Sheet analyzed
e
Client Name: TRC Environmental Corporation
Job#: 202011869 A^olume (milliters): 50
Lab Sample #: 01 Dust Sample Area: 100
Client Sample #: SN011102MVAIR0201 Filter Type / Filter Area: MCE 214 mm2
Received: 01/12/2002 09:33:47 Crrid opening Size: 0.01000
Date Analyzed: 01/14/2002 Area Examined: 0.10000 mm?
Scope #: Dilution Factor: 0.0200 Magnification: 20,000
________________________ _____ Accelerating Voltage: 100 KeV
Analysis Performed by:
Mark Peysakhtjv
Location Grid Length Width
Opening Fiber gM gM Fiber Type MoiTshology EDS Orient. SAED Photo
C1-F4/4 1 1 1.5 0.1 Chrysotile B/F/M Mg, Si, Fe 1^
C1-E4/6 2 3.2 1.5-18 0.01 Chrysotile F/B Mg, Si, Fe
C2-C4/1 3 1,2 2-75 0.05-1 Chrysotile F/B Mg, Si, Fe
C2-E4/1 4 3 1-3 0.05-0.1 Chrysotile F/B Mg, Si, Fe
C2-F4/1 5 4.1 1.5-8 0.05 Chrysotile F/B Mg, Si, Fe 1^
C2-G4/1 6 1 1.2 0.05 Chrysotile Fiber Mg, Si, Fe
C2-H4/1 7 1,1 2-8 0.05 Chrysotile Fiber Mg, Si, Fe
C2-K4/1 8 0,1 15 0.05 Chrysotile Fiber Mg, Si, Fe
C2-G3/1 9 3,1 1.5-9 0.05 Chrysotile Fiber Mg, Si, Fe
^H3/l 10 4,1 1.2-9 0.05 Chrysotile Fiber Mg, Si, Fe 1^
NSD; No Asbestos Structures Detected
Comments:
Structure Density Grid Evaluation
Total Grid Openings; 10 (str/sq mm) Grid Openings Covered > 50%
Chrysotile Asbestos Structures; 30 300.0 Intact Grid Opening > 50%
Amphibole Asbestos Structures: 0 <10 13 Undissolved Filter < 10%
Asbestos Structures >=5 microns; 9 90.0 3 Folded Replica < 50%
Total Asbestos Structures; 30 300.0 3 Filter Loading < 25%
Analytical Sensitivity: 10 3 Particulate Even