Page image not rendered yet. The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text
OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
sample area
TEM Asbestos (dust) Count Sheet analyzed
Client Name: TRC Environmental Corporation
Job#; 202013197 ^^olume(millitersV, 100
Lab Sample #: 02 Dust Sample Area: 100
Client Sample #: JD012502MV0606 Filter Type/Filter Area: MCE 214 mm2
Received: 01/25/2002 17:25:00 Grid Opening Size: 0.01000
Date Analyzed: 01/28/2002 Area Examined: 0.10000 mm2
Scope #: Dilution Factor: 0.0200 Magnification: 20.
Accelerating Voltage: 100 KeV y
Analysis Performed by: 70^
Roman Peysakhov
Grid Length Width
Location Opening Fiber MM mM Fiber Type Moiphology EDS Orient. SAED Photo
E1-4/1C 1 NSD □
E1-4/1E 2 NSD u
E1-4/4F 3 NSD u
E1-4/4G 4 NSD u
E1-4/1K 5 NSD u
E2-4/1B 6 NSD u
E2-4/1C 7 NSD u
E2-4/1E 8 NSD u
K-4/1F 9 NSD u
10 NSD u
W
NSD; No Asbestos Structures Detected
Comments:
Structure Density Grid Evaluation
Total Grid Openings: 10 (str/sq mm) K Grid Openings Covered > 50%
Chrysotile Asbestos Structures: 0 <10 Intact Grid Opening > 50%
Amphibole Asbestos Structures: 0 <10 S Undissolved Filter < 10%
Asbestos Structures >=5 microns; 0 <10 Folded Replica < 50%
Total Asbestos Structures; 0 <10 ^Filter Loading < 25%
Analytical Sensitivity; 10 Particulate Even
CITY_21 MCI 00_014547264
NYC-WTC_000234957
OCR can misread numbers and units. Confirm readings against the page image before using them.
NYC-WTC_000234957Source: NYC Law Department, mirrored locally