NYC 9/11 Public Portal Document
TRC Environmental Consultants
A. EMSL Analytical Inc. 1430 Broadway, 10th Floor
Customer ID;
Customer PO;
TRCES1
EMSL 307 West 38th Street, Now York, NY 100 IB New York, NY 10018 Received; 06/18/05 10:26 Al.
(212) 290,0051
EMSL Order: 030516707
Fax: (212)221-7840 Phone: (212)221-7822
EMSL Proj: 130 Liberty Street
Project; LMDC/ URS/130 LIBERTY
Asbestos Analysis of Bulk Material Report Date: 6/21/2005
Analyzed Non Asbestos
Sample Description Test Dale Color Fibrous Non-Fibrous Asbestos Comments
022 PLM NYS 198.1 Friable Not Analyzed
0305/6707-0022
PLM NYS 198.1 NOB 6/20/2005 Green/Gray N/A inconclusive: None Detected
ALUMINUM COVER CAULKING/ H-S TEM NYS 198.4 NOB 6/20/2005 Green/Gray N/A 1.5% Chrysotile
1.5% Total
023 PLM NYS 198.1 Friable Not Analyzed
0305-16707-0023
PLM NYS 198.1 NOB 6/20/2005 Green/Gray N/A Inconclusive; None Detected
ALUMINUM COVER CAULKiNG/ H-5 TEM NYS 198,4 NOB 6/20/2005 Green/Gray N/A 3,1% Chrysotile
3.1% Total
024 PLM NYS 198.1 Friabie Not Analyzed
030516707-0034
PLM NYS 198.1 NOB 6/20/2005 Green/Gray N/A Inconclusive: None Detected
ALUMINUM COVER CAULKING/ H-5 TEM NYS 198.4 NOB 6/20/2005 Green/Gray N/A 4.1% Chrysotile
4.1% Total
NOB = Non Friable Organically Bound
N/A = Not Applicable
AnalyEt(s)
Aline Fontaine
Marik Peysaktmv
Jose Arriaga
or other approved signatory
EMSL mairstains liability limited to cost of analysis. This report relates only to the samples reported above and may not be reproduced, except in full, without written approval by EMSL. The above lest report relates only to the items tested. This
o test report must not be used to claim product endorsement by NVLAP or any agency of the U.S. Government. EMSL bears no responsibility for sample colleclion activities or analytical method limitations. The results in this report meet all
requirements of the NELAC Standards unless otherwise nolad. The laboratory is not responsible for the accuracy of results when requested to physically separate and analyze layered samples. PLM is not consistently reliable in detecting
asbestos in floor coverings end similar NOD's. Quanlitative TEM is currently the only method that can be used to determine if a NOB material can be considered or treated as non-asbestos containing.
1"^
to
ACCREDITATIONS; NVLAP #101048-9 and NY STATE ELAP #11506