208 Stoneliiiige Lane EMSL Analytical, Inc. Carle Place, NY 12524 EMSk' Phone: (526) 997-7251 Fax: (516) 997-752S Attn.: Taylor Environmental Group, Inc. Friday, February 22, 2002 Floral Park Coroorate Center 130-A Jericho Tpke. Ref Number: LI023032 Floral Park, NY 11001
Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed by EPA 40 CFR Part 763 Final Rule ( AHERA) rn A lA > Project: SCA 100 TRINITY PL.
r STRUCTURES Analytical Volume Asbestos > O.Sii - Non* Area Analyzed Sensitivity ■Asbestos Concentration Sample ID niters) Type(s) < 5u 5u Asbestos (mm') (S/cc) (S/mm’) (S/cc) F-07 ■180100 None Detected 0 0.0508 0.0042 <19.69 <0.0042
,--08 1900.00 None Detected 0 0.0508 0.0040 <19.69 <0.0040
F-09 1900.00 None Detected 0 0.0508 0.0040 <19.69 <0.0040
.=-10 1853.00 None Detected 0 0.0508 0.0041 <19.69 <0.0041
11 1805.00 None Detected 0 0.0508 0.0042 <19.69 <0.0042
F-12 1805.00 None Detected 0 0.0508 0.0042 <19.69 <0.0042
Earl Tracey Analyst Approved Signatory Disclaimers: This laboratory is not responsible for oaia rcboneO in stnjctufes/cc. wnicn is oecienaent on volurr^ collected Dy non«laDOfBtory personnel. This laboratory is only resoonsible for oata reported m suuciures/mrrf. This reoon may not be reoroduced. excepi in full, without wntten aoproval by EMSL This reoon mrsi not be used to daim proouci enoorsemeiit oy NVLAP or any agency of Ine U.S. Government. This reoon relates only to me samoies reponeo above. Quality control oata (inauding 95% confinence limis and laooraiory and analysts' accuracy ano oreasion) is availaole uoon request 2
CITY_21MC1OO_O1O21824O
NYC-WTC_000232355
OCR can misread numbers and units. Confirm readings against the page image before using them.
Related records
Browse subjects →Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
Same-box records
No available related records indexed in this group.
Filed elsewhere
6 shared non-person entities · 1 shared topics · similarity 0.986
machine-extracted · confidence unavailable · Check page ↗5 shared non-person entities · 1 shared topics · similarity 0.977
machine-extracted · confidence unavailable · Check page ↗5 shared non-person entities · 1 shared topics · similarity 0.976
machine-extracted · confidence unavailable · Check page ↗5 shared non-person entities · 1 shared topics · similarity 0.976
machine-extracted · confidence unavailable · Check page ↗5 shared non-person entities · 1 shared topics · similarity 0.975
machine-extracted · confidence unavailable · Check page ↗5 shared non-person entities · 1 shared topics · similarity 0.975
machine-extracted · confidence unavailable · Check page ↗5 shared non-person entities · similarity 0.975
machine-extracted · confidence unavailable · Check page ↗5 shared non-person entities · 1 shared topics · similarity 0.975
machine-extracted · confidence unavailable · Check page ↗5 shared non-person entities · 1 shared topics · similarity 0.975
machine-extracted · confidence unavailable · Check page ↗5 shared non-person entities · 1 shared topics · similarity 0.975
machine-extracted · confidence unavailable · Check page ↗5 shared non-person entities · similarity 0.975
machine-extracted · confidence unavailable · Check page ↗More like this page
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Similarity score 0.988 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.988 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000106851
Certification that floors 6-11 of school building meet re-occupancy criteria based on post-cleaning visual inspection and air sample testing.
Similarity score 0.987 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000106851
Certification that floors 6-11 of school building meet re-occupancy criteria based on post-cleaning visual inspection and air sample testing.
Similarity score 0.986 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.985 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.985 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Others also read
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
Similar indexed content
Similar indexed content
Similar indexed content
Similar indexed content
Similar indexed content