■ 1 I -J TEM Asbestos (air) Count Sheet sample area analyzed H Client Name: Riverpoint, Inc. Job#: 201103187 Volume (liters): 675.0 1 Lab Sample #: 28 u Client Sample #: 191022 Filter Type / Filter Area: MCE Grid Opening Size: 0.01000 385 mm2

Received: 10/23/2001 07:30:00 Area Examined: 0.10000 mm2 Date Analyzed: 10/24/2001 Magnification: 20,000 Scope #: >^^Ac(^lcrating Voltage: 100 KeV Analysis Performed by: vTikhail Gruzman Grid Length Width Location Opening Fiber Fiber Type Morphology EDS Orient. SAED Photo ;tM ;tM E3-B4/6 1 NSD □ E3-C4/6 2 NSD u D E3-E4/6 E3-F4/6 3 4 NSD NSD u u E3-G4/6 5 NSD u E3-H4/6 6 NSD u E3-K4/6 7 NSD u E4-F4/6 8 NSD u E4-G4/6 9 NSD u E4-H4/6 10 NSD u

NSD: No Asbestos Structures Detected Comments Modified TEM Level II reports only asbestos fibers >=5 microns in length Structure Density Concentration (str/mm2) (str/cc air) Grid Evaluation Total Grid Openings: 10 Chrysotile Asbestos Structures: 0 <10 <0.0057 IHl Grid Openings Covered > 50% Amphibole Asbestos Structures: 0 <10 <0.0057 13 Intact Grid Opening > 50% <10 <0.0057 13 Undissolved Filter < 10% Asbestos Structures >=5 microns: 0 Total Non-Asbestos Structures: 13 Folded Replica < 50% Total Asbestos Structures: 0 <10 <0.0057 3 Filter Loading < 10% Analytical Sensitivity: 10 0.0057 3 Particulate Even

CITY_21MC100_008880403

NYC-WTC_000231587

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000231587Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →