NYC 9/11 Public Portal Document A.i'. •. hl-.!

fe* itrodaction October 17,2001

Gateway Plaza Management Corporation 375 South End Avenue New York. New York 10280

Subject; Gateway Plaza Building #300

Gentlemen:

ALC Environmental Incorporated (ALC) has been contracted by to perform visual assessments, bulk sampling, and air sampling to identity any asbestos contaminant at ths above referenced building. AJ_C performed sampling according to the EPA Guidelines for asbestos bulk sampling and air sampling. The inspections were conducted in this building on September 23. October 5 & 12, 2001,

ALC worked under the guidance provided by the EPA guidelines for asbestos-in gai/efthgr.' Simplify Samolins Scheme for Frigbie Surfacins Materials" and the direction of the Department of Environmental Protection (DHP) to perform the faulk sampie collection and analysis. Additionally, ALC provided on site Third Party Air Monitoring and Project Management, which included performing area air sampling on each floor of the building, supervising the clean-up activities in specific apartments where minimal asbestos was found-even though further analysis at a second laboratory showed the results to be below the permissible limits-, performing quality assurance inspections and monitoring the work practices of ths Asbestos Abatement Contractor. Air Sampling was conducted in accordance with Federal Slate and I Local regulations including New York City Department of Environmental Protection (NYC-DEP) Title 15, Chapter 1, Asbestos Control Program Subchapter D, “Air and Bulk Sampling, Monitoring and Analysis; and New York State Department of Labor Industrial Code Rule 56 (NYS-DOLICR56) Section 56-17 “Air Sampling, Monitoring and Analysts,”

ALC is licensed to perform asbestos activities by the Slate of New York Department of Labor (License # 00-0353). ALC employs only certified asbestos personnel to perform required tasks. The following personnel were used to perform asbestos air monitoring and/or asbestos inspections.

Project Manager Inspector/Project Monitor/Sampling Technician: Americo Rodriguez Jr, (License #AH 89-07160) Inspector; Alvin R, Blake (License #AH 00-08397)

ATC Associates 104 East 25'*' Street New York, New York analyzed all samples. Further analysis was performed by SciLab 117 East 30'’' Street New York, New York.

If you have any questions or comments please do not hesitate to contact us directly at 212-279-1001,

Sinci

Joshi Sarett Enpronmental Incorporated

mcicn CITY_21MC100_008873482

NYC-WTC_000230934

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000230934Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000117757 · Box DEP Box 46

Cover page for a report detailing annual assessment, bulk sampling, and air monitoring activities at the specified address.

Similar indexed content

NYC-WTC_000117493 · Box DEP Box 46

Cover page for a report detailing annual assessment, bulk sampling, and air monitoring activities at the specified address.

Similar indexed content

Compare copies and versions →