Pace Analytical Services, Inc. 1700 Elm Street, Suite 200 • I 'aceAnalyticar Minneapolis, MN 55414 Phone: 612.607.1700 www.pacelabs.com Fax: 612.607.6444 TABLE 2. High Resolution PCDD/PCDF Analyses HRGC/HRMS Operating Parameters -A."

Mass Resolution 10,000-11,000 (M/AM, 10% valley)

Electron Energy 32 electron volts

Accelerating Voltage 8,000 volts

1 a Source Temperature 275°C

r Preamplifier Gain

Multiplier Gain 10 ® amp/volt

"10®

I Chromatographic Column 60 M DB-5MS

a Transfer Line Temperature 260°C

Injection Mode Splitless

s Carrier Gas Helium

*3 Carrier Flow Velocity "30 cm/sec ■a

I ■1

1

sS •

i 1. 23 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced; except in full,-.... without the written consent of Pace Analytical Services, Inc. 1 CITY_21MC100_000490786 NYC-WTC_000226887

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000226887Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →