Mr. Bernard P. Orlan February 20, 2002 Wipe Samples for Dioxins Page 2 P. S. 234 (Manhattan) ATC Project No. 15-19125-0279

The New York State Department of Health (NYSDOH) established guidelines for dioxin for the re-occupancy of the Binghamton State Office Building following a PCB fire. The NYSDOH guideline for dioxin on surfaces is 25 nanograms per square meter (25 ng/m^). The New York State Department of Environmental Conservation (NYSDEC) has set 0.0006 parts per million (ppm) as the allowable concentration of dioxin in soil. The EPA has established a residential clean-up goal of 1 part per billion (ppb).

WIPE SAMPLING RESULTS

ATC submitted two (2) wipe samples for PCDDs/PCDFs (plus one blank) to Pace for analysis. Copies of the draft analysis results are provided in Attachment 1. Samples were taken from areas specified by the parents association consultant. The area of each sample one (1) square meter ( 1 m^).

Each sample was analyzed for sixteen (16) PCDD/PCDF isomers. The results for each isomer were then converted to 2, 3, 7, 8 -tetrachloro-dibenzo-p-dioxin (2, 3, 7, 8-TCDD) equivalents by multiplying by an established equivalency factor (See Attachment). This provides a single value (in nanograms) for the analytical results for each sample. The sample locations and the results are shown in the table: DIOXIN WIPE SAMPLE RESULTS (2, 3, 7, 8 TCDD EQUIVALENTS)

LOCATION/SAMPLE NUMBER 1 st Floor Hallway - east end/DXl ” 0.6053 1 st Floor Hallway - west end/DX2 U.D033 Blank/DX3 0.000073

The concentrations on indoor surfaces ranged from 0.0033 to 0.0053 nanograms per square meter (ng/m^). These levels are well below the NYSDOH guideline.

It is not possible to determine when the 2, 3, 7, 8 - TCDD equivalents detected in these samples were deposited. Dioxin wipe samples were not collected from this school prior to December 6, 2001.

It is our pleasure to provide these indoor environmental services to the NYC Board of Education. If you have any questions about this report, please call (212) 353-8280, extension 212.

Sincerely, /I TC ASSOCIA TES^C.

James R. Cohn, CIH, CSP Regional Manager, Industrial Hygiene Division

Attachment

CITY_21MC1OO_OO289116O

NYC-WTC_000223534

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000223534Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →