Dec IS 01 02:SSp PSC Analytical Services 610321SBG7 p. 5

F’SC INDUSTRIAL HYGIENE • EP/VNVLAP101252-0 •AIHAACCREDITATIONNO. 100439 -NCDENR59g ENVIRONMENTAL TESTING -NY DOH/NELAC10903 ■ PADEP06-353 •NJDEP77QZO • CT DPH PH-0238

ANALYTICAL SERVICES Analytical Results for ATC Associates WorkOrder: R0n20i69 Client Reference: 19125-0246: PCBs in Air (12/8/01)

Analyte Concentration Limit of Test Date Analyzed Detection Method /Analyst (ug) : (mg/m’) : (ppm) (ug) Client IO: PCB9-ATC.I208-234M, Blank Lab ID: -09A Date Sampled: 12/S/Ol Matrix: Ten ax Air Vol.(L): NA Aroclor 1016 <0.5 0.5 POLYCHLORINATED 12/1672001 GIF Aroclor 1221 <0.5 0.5 POLYCHLORINATED 12716/2001 GIF , Aroclor 1232 <0.5 0.5 POLYCHLORINATED ,.12/16/2001 GIF Aroclor 1242 <0.5 0.5 POLYCHLORINATED 12/16/2001 GIF Aroclor 1240 <0.5 0.5 POLYCHLORINATED 12/16/2001 GIF. Aroclor 1254 . <0.5 0.5 POLYCHLORINATED 12/16/2001 GIF "Aroclor 1260 <0.5 0.5 POLYCHLORINATED 12/16/2001 GIF (a) Analysis indicates possible breakthrough; back section result is greater than % of the front section result.

General Notes: <: Less than the indicated limit of detection (LOD). -: Information not available or not applicable. Back sections were checked and showed no significant breakthrough.

Page 3 of 3

I

CITy_21MC100_002890863

NYC-WTC_000223516

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000223516Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000177927

Laboratory report detailing analytical results for PCBs, metals, PAHs, and cyanide from samples collected at P.S. 234M.

Similar indexed content

Compare copies and versions →