NYC 9/11 Public Portal Document

Mr. Bernard P. Orlan May 22, 2002 Wipe Samples for Dioxins Page 2 Stuvvesant High School (M477) ATC Project No. 15-19125-0246

Each sample was analyzed for sixteen (16) PCDD/PCDF isomers. I he results for each isomer were then converted to 2, 3, 7, 8 tetrachloro-dibenzo-p-dioxin (2, 3, 7, 8-TCDD) equivalents by multiplying by an established equivalency factor. This provides a single value (in nanograms) for the analytical results for each sample. A copy of the laboratory analysis report is attached. The results are shown in the following table.

DIOXIN WIPE SAMPLE RESULTS 2,3,7, 8 TCDD EQUIVALENTS - Nanograms per square meter (ng/m^)

May 1, 2002 LOCATION /SAMPLE ID DIOXIN CONCENTRATION

1” Floor Lobby 0.000043 Main Entrance / DXl 2^ Floor Lobby 0.000036 Bridge Entrance /DX2 HVAC#I/DX3 0.017

The New York State Department of Health (NYSDOH) established guidelines for dioxin for the re-occupancy of the Binghamton State Office Building following a PCB fire. The NYSDOH guideline for dioxin on surfaces is 25 nanograms per square meter (25 ng/m2).

The concentrations on indoor surfaces ranged from 0.000036 to 0.017 nanograms per square meter (ng/m2). The levels found in all of these samples are below the NYSDOH guideline of 25 ng/m2.

It is not possible to determine when the 2, 3, 7, 8 - TCDD equivalents detected in this sample was deposited. Dioxin samples were not collected from these locations prior to November 8, 2001, and therefore a background sample is not available for comparison purposes.

It is our pleasure to provide these indoor environmental services to the NYC Board of Education. If you have any questions about this report, please call (212) 353-8280, extension 212.

Sincerely, ATC Associates, Inc.

Reviewed by:

icl J/vAl James R. Com, CIH/CSP ienion Woject Manager Regional Manager Industrial Hygiene Division

Attachment

CITY_21MC100_002890007

NYC-WTC_000223249

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000223249Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →