weAnalvticar_________ Method 8290 Analysis Results
Tel: 612.6O7-170O
Pax- etg- 607-6444
Client - ATC
Clients Sample ID ATC-0222-234M-DX2
Lab Sample ID 103343372
Fitename U20311A_15
injected By CVS
Total Amount Extracted 1 m2 Matrix WIPE
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 02/22/2002
ICAL Date 03/11/2002 Received 02/25/2002
CCat Filename(s) U20311A_07 & U20311 A_22 Extracted 03/05/2002
Method Blank IO BLANK-1499 Analyzed 03/11/2002 23:06
Native Cone EMPC URL Internal ng's Percent
Isomers ng/mZ ng/m2 ng/m2 Standards Added Recovery
2.3,7,8-TCDF ND — 0.0033 A 2,3,7,8-TCDF-13C 2.00 78
Total TCDF ND ---- 0.0020 2,3,7,8-TCDD-13C 2.00 69
1,2,3,7,8-PeCDF-13C 2.00 88
2,3.7,8-TCDD ND 0.0056 A 2,3.4,7,8-PeCDF-l3C 2.00 90
Total TCDD ND 0.0020 1,2,3,7,8-PeCDD-13C 2.00 85
1,2.3,4,7,B-HxCDF-13C 2.00 127
1,2,3,7,8-PeCDF ND 0.0100 1,2,3.6,7,8-HxCDF-13C 2.00 92
2,3,4.7.8-PeCDF ND 0.0100 2,3,4,6,7.8-HxCDF-13C 2.00 97
Total PeCDF ND 0.0100 1,2,3,7,8.9-HxCDF-13C 2.00 107
1,2,3.4.7,8-HxCDD-13C 2.00 119
1.2,3,7,8-PeCDD ND 0.0100 1,2,3,6,7,8-HxCDD-13C 2,00 74
Total PeCDD ND 0.0100 l,2,3,4,6,7.8-HpCDF-13C 2.00 91
1,2,3,4,7,8,9.HpCDF-13C 2.00 10O
1,2,3,4,7,8-HxCDF ND 0.0100 1,2,3.4,6,7.8-HpCDD-13C 2.00 95
1,2,3,6.7.8-HxCDF ND 0.0100 OCDD-13C 4.00 93
2,3,4,6.7.B-HxCDF ND 0.0100
1,2,3,7,8,9-HxCDF ND 0.0100 1.2.3,4-TCDD-13C 2.00 NA
Total HxCDF . ND 0.0100 1,2,3,7,8,9-HxCDD-13C 2.00 NA
1,2,3,4,7.8-HxCDD ND 0.0100 2.3.7,8-TCDD-37CI4 020 72
1,2,3,6,7.8-HxCDD ND 0.0100
1.2.3.7,8,9-HxCDD ND 0.0100
Total HxCDD ND 0.0100
1.2,3,4,6.7.8-HpCDF ND 0.0100 Total 2,3.7,8-TCDD
1,2,3,4,7,8,9-HpCDF ND 0,0100 Equivalence: 0.000081 ng/m2
Total HpCDF ND 0.0100 (Using ITE Factors)
1.2,3,4.6,7.8-HpCDD ND 0.0100
Total HpCDD ND 0.0100
OCDF ND 0.0200
OCDD 0.081 0.0200 BJ
LRL = Lower Reporting Limit
Cone Concentration (Totals Inotudo 2,3,7,8-sul5etliutad isomers) IX Interference
EMPC > EStImued Maxtnum Possible Coneaniration E = PCDE Intarfersnce
AisD 1 UmR BasM on sfcnal-to-noisB (nsaturarnent S B Saturated signal
J = Concentration detected Is below the calibration rsnga ND = Not Detoelad
B s Uss than 10 times higher than method Mank level NA X Not Applicable
P > Recovery outside of target range NC = Not Calculated
Nn s Value obtained from additional analysis ’ = See Discussion
Report No.... 02-1054414
REPORT OF LABORATORY ANALYSIS
This report Shan not ba reproduced, except In full,
without the written consent of Pace Analytical Services, Inc.