NYC 9/11 Public Portal Document
.Attn: Mr. Bernard Orlan Received; .3/8/02 9:00:00 PM
N.Y.C. Board of Education ATC Group #: 6991
28-11 Queens Plaza North Analysis Date: 3/9/02
Long Island City, NY 11101
• Fax: (212) 475-4122 Phone: (212) 477-8941
Pro,j.ect: New Stuyvesant H. S. , 345 Chambers St., NY , NY
Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed
by EPA 40 CFR Part 763 Final Rule (AHFRA)
Analytical Asbestos
Area Non Asbestos # Structures Sensitivity Concentration
Sample i'oltime Analyzetl Asb Type(s) 0.5fi-5 5fi (S/cc) (S/mm-) (S/cc) Notes
19 1920.00 0.0450 0 None Detected 0 0 0.0045 <22.24 <0.0045
6991 -19.
20 1936.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044
6991 -20
21 1936.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044
6991 -21
MARK PEYSAKHOV MICHAEL A. GORYCKI, Ph.D.
Analyzed by: Approved by:
Disclaimer: The laboratory is not responsible (or data reported in structures/cc. which is dependent on volume collected by non-laboraiory personnel. This lab is only responsible
(or data reported in structures/mm’. This report may not be reproduced, except in (ull, without written approval by ATC Associates Inc, This report may not be used to claim
product endorsement by NVLAP or any other agency o( the U.S. Government. This reports relates only to the samples reported above Quality control data (including 96%
confidence limits and laboratory and analysis' accuracy and precision) is available upon request.
Accredited (or NVLAP FLMCEM #101187-0, NY State ELAP #10879
CITY_21MC100_0 02876091