NYC 9/11 Public Portal Document
TEM Asbestos (air) Count Sheet
Client Name: NYC BOE Volume (liters); 1808
Lab Group #: 8278 Filter Type / Filter Area: MCE 385 mm^
Lab Sample #: 14 Grid Opening Size; 0.01124
Client Sample #: 16 Area Examined; 0.04496 mm^
GRID BOX: Magnification: 20,000
GRID ID: Accelerating Voltage: 100 KeV
# Grid Openings: 4 Analysis Date: 6/25/02
Analysis Performed By:
MARKPEYSAKHOV
GO. Structure Structure Type Length ID of Structure N or v EDS
(Nonadb
No F B C M >=05 p >=5p Chrys Amphibole Nonasb Ambig/ND
No Coord <5p Elements)
Struct = > 0.5|i >5:1 Aspect Ratio Grid acceptance:
Positive diffraction pattern properties confomiing to <50% undissolved filter, overiapped or folded Totals
laboratory identification criteria observed <10% particulate coverage >50% coverage ate
EDS spectrum conforming to laboratory
least 20 unfolded or overiapped grid squares <5%
holes or opaque areas
F B c M >5p
identification criteria observed Chrysotile
AMPHIBOLES Amphibole
F = Single Fiber Amosite
B = Bundle (<3 fibers <1 fiber diameter apart Crocidolite Ambiguous
C = Cluster (>3 Intersections) Anthophyllite Non-Asbestos
Tremolite
M = Matrix Non-Identified
Acfinolite
NSD = No Structures Detected
CITY_21MC100_002870100