NYC 9/11 Public Portal Document
GCI ENVIRONMENTAL ADVISORY, INC
655 Third Avenue New York NY 10017 (212) 986-9460 Fax: (212)986-9464
September 28, 2001
Mr. Frank Vasta
Rockrose Development Corp.
309 East 45’^ Street
New York, NY 10017
Re: 99 John Street, NYC - Apt. 101 1
Dear Mr. Vasta,
GCI Environmental Advisory, Inc. has collected ambient air samples within the above
referenced apartment as well as the apartments and common areas of the above
referenced building during September 20 - 26, 2001.
Air sampling was conducted within the apartment utilizing 0.8 u, MCE sampling
cassettes employing high volume air sampling pumps during "normal" building
activities.. A minimum of Nine Hundred (900) liters of air was collected to provide a
detection limit below 0.01 f/cc (fibers per cubic centimeter). All samples were pre-
and post-calibrated by means of a precision rotometer that had been calibrated with
a primary standard. Sampling blanks were collected and submitted with each group
of samples analyzed. Air sample analysis was according to NIOSH Analytical Method
7400 with results reported as fibers per cubic centimeter (f/cc). Laboratory Analysis
performed by an ELAP approved and NIOSH PAT proficient laboratory.
Laboratory analysis indicated airborne levels below the current recommended
"Clearance Air Criteria" of 0.01 fibers per cubic centimeter (f/cc) of air according to
Phase Contrast Microscopy (PCM).
Should you have any questions or need additional information, please contact me at
(212) 986-9460.
Sincerely,
recent
iCI Environmental Advisory, Inc.
JFG/gj
GCI ENVIRONMENTAL ADVISORY, INC. PROJECT 2001 N01-B4085.99.APT.PCM