NYC 9/11 Public Portal Document

Mr. Bernard P. Orlan June 13, 2002 Respirable Particulate Monitoring Page 2 Various Ix)cations/Manhattan ATC Project No. 15-19125-0314

TARGET GUIDEL NES FOR AIR QUALITY PARAMETERS EVALUATED* PARAMETER TARGET LEVEli Ui j Y: Respirable 65 micrograms per cubic Particulates meter of air (pg/m3) 24 hour USEPA NPAAQS (PM2.5) average Respirable USEPA recommendation Particulates 40 |J.g/m3 24 hour average for children/sensitive (PM2.5) individuals USEPA = United States Environmental Protection Agency NPAAQS = National Primary Ambient-Air Quality Standard REAL-TIME SAMPLING RESULTS

Thirty-one (31) indoor and thirty-four (34) outdoor respirable particulates measurements* were collected from twenty-nine (29) school locations in Manhattan, ranging from West 11th Street to East Street. The measurements were made from 5:54 A.M. to 4:37 P.M. The lAQ field report forms are provided as the Attachment.

The outdoor PM2.5 concentrations ranged from 139 pg/m^ to 182 pg/m^ with an average of 167 pg/m^. The indoor concentrations ranged from 97 pg/m^ to 168 pg/m3 with an average of 145 pg/m^. All of the indoor and outdoor readings were above the NPAAQS of 65 pg/m^ 24-hour average concentration of particulate matter 2.5 micrometers or less in aerodynamic diameter and above the USEPA recommended guideline for children and sensitive individuals of 40 pg/m3.

* These measurements were instantaneous readings, the NPAAQS and the recommendation for children are 24-hour averages.

CONCLUSION Based on our measurements, all of the indoor and outdoor readings were above the NPAAQS of 65 pg/m^ 24-hour average concentration of particulate matter 2.5 micrometers or less in aerodynamic diameter and above the USEPA recommended guideline for children and sensitive individuals of 40 pg/m^.

It is our pleasure to provide these air quality consultative services to the New York City Board of Education. If you have any questions about this report, please call (212) 353-8280, extension 212 or 211.

Sincerely, ATC ASSOCIATES INC. ^eid^wed-byy-~y^x^ )

<>Yiannis Efstaithiou James R. Cohn, CIH, CSP Senior Project Manager Regional Manager, Industrial Hygiene Division

Attachment

CITY_21MC100_003018275

NYC-WTC_000208015

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000208015Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →