NYC Law Department release
Independent mirror · updated as the City releases more · v1.3.2
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 3 pages

NYC-WTC_000205198

Label derived from the City's folder field. The City does not supply document titles.NYC-WTC_000205198–000205200
Page image
Scanned page image, NYC-WTC_000205199
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

■power tools during demolition activities at 7 WTC’s parking garage. Most of the work areas where apparent overexposures to silica occurred were in the rubble pile/pit; an area where OSHA continues to encourage the use of respiratory protection. Organic Compounds: OSHA has taken a total of 625 samples (excluding bulk and blank samples) for organic compounds such as acetaldehyde, acrolein, acrylonitrile, benzene, 2-butanone, carbofurans, dioxin, PCBs, ethyl benzene, formaldehyde, Freon R-22 (chlorodiflouromethane), hexone, isocyanates (e.g. MDT, TDl), perchloroethylene, polynuclear aromatics, phosgene, styrene, toluene, 1-3 butadiene, tnchloroethylene, vinyl chloride, glutaraldehyde, and xylene. Screening samples initially showed elevated levels of some organic chemicals resulting from the fires burning in the rubble pile. Subsequent personal and area samples show worker exposure levels to he below OSHA limits. However, one personal sample result for a benzene sample taken was found to be at the 8- hr. OSHA Allowable Limit concentration of 1 ppm. This was found on a backhoe operator moving debris on 10/7/01. Sec information below for the specific counts in regards to polynuclear aromatics. Freon R-22, phosgene and dioxin.

Dioxins: OSHA has taken 10 dioxin samples (excluding blanks) in the plume over hot spots in (and around the perimeter of) the rubble pile. Dioxin levels detected around the perimeter are lower than those found directly over the pile. To date, only one sample taken on the rubble pile showed dioxin levels which exceeded background levels. Dioxins are considered collectively as suspect human carcinogens. OSHA does not have a PEL for dioxins. Poiynuclear Aromatic Hydrocarbons OSHA has taken 110 samples (excluding blanks). The majority of the samples have not shown the presence of benzo(a)pyrene and/or one or more of five additional fused polycyclic hydrocarbons: anthracene, acridine, pyrene, chrysene and phenanthrene. Sample results to date have identified eight samples which reached or exceeded OSHA’s coal tar pitch volatile PEL of 0.2mg/m’. These personal samples were taken on the pile on iron workers and grappler operators. OSHA continues to strongly recommend the use of respiratory protection when working on the rubble pile. Freon R-22, Hydrogen Fiuoride & Phosgene: OSHA has taken a total of 202 samples for Freon R-22 (chlorodiflouromethane), hydrogen fluoride, and phosgene. Only one Freon sample resulted in a detectable level of 6.4 ppm during the transfer of Freon from the auxiliary chiller, and all other samples were none-detected. OSHA does not have an exposure limit for Freon R-22. (The NIOSH

Page 2 of 3

CITY_21MC100_007222304

NYC-WTC_000205199

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000205199Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →