Summary of Asbestos Sampling Results Page 2 of 2

Address: 110 Greenwich St. Date sampled: Dec 3, 2001

Air samples

Airborne fibers as determined by Phased Contrast Microscopy (PCM): An air sample is collected by pulling air through a filter. The filter catches fibers and is then sent to a laboratory to determine what types of fibers were in the air. Phase contrast microscopy identifies fibers based on size and shape, but not mineral composition. Therefore, the fibers seen by PCM include asbestos fibers as well as other fibers, such as textiles, fiberglass, cellulose, which might be present in your home. By counting all fibers, we are being more protective of your health when we compare this to our screening value for asbestos fibers.

(Area Sampled Outside Common Residence 1 Residence 2 [Sample Numbers A-0-28 A-C-28 A-Rl-28 A-R2-28 Concentration of Fibers in Air <.001 .001 <.001 .002 [at this location Concentration of Fibers in Air <.001 <.001 to .003 <.001 to .003 <.001 to .003 [at background locations Screening Value** .01 f/cc .01 f/cc .01 f/cc .01 f/cc

**Screening Value - The NYC standard for asbestos in community and residential buildings is 0.01 fibers/cubic centimeter (f/cc) in indoor air. This standard is used for re-occupancy in an indoor area where asbestos was detected and removed.

C:\TEMP\SuniiTiaryof Asbestos Sampling Resultsl228Gl.doc

CITY_21MC100_003062437

NYC-WTC_000204851

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000204851Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →