Mr. Bernard P. Orlan March 20, 2002 Wipe Sampling for Dioxin Page 2 P. S. 150 (Manhattan) ATC Project No. 15-19125-0289

RESULTS

ATC' submitted one wipe sample for PCDDs/PCDFs (plus one blank) to Pace for analysis. The sample area was Isquare meter (Im^). The location sampled was the Main Entrance - Lobby.

The sample was analyzed for sixteen (16) PCDD/PCDF isomers. The results for each isomer were then converted to 2, 3, 7, 8 -tetrachloro-dibenzo-p-dioxin (2, 3, 7, 8-TCDD) equn alents by multiplying by an established equivalency factor. This provides a single value (in nanograms) for the analjlical results for each sample. Copies of the draft laboratory' analysis results are attached. The results of the samples are shown in the following table:

DIOXIN WIPE SAMPLE RESULTS (2, 3, 7, 8 TCDD EQUIVALENTS) February 22,2002 LOCATION/SAMPLE NUMBER 5 DIOXIN CQ.XCENTRATKJN

MAIN ENTRANCE - LOBBY/DXl 0.00094 ng/m2

FIELD BLA\K. i JN2 0.00034 ng/m2

ITie New York State Department of Health (NYSDOH) established guidelines for dioxin for the re-occupancy of the Binghamton State Office Building following a PCB fire. The NYSDOH guideline for dioxin on surfaces is 25 nanograms per square meter (25 ng/m^).

The dioxin concentration in this sample is below the NYSDOH guideline. It is not possible to determine when the 2, 3, 7, 8 - TCDD equivalents detected in this sample was deposited. Dioxin samples were not collected from this location prior to December 13, 2001.

[t is our pleasure to provide these indoor environmental services to the NYC Board of Education. Ifyou have any questions about tins report, please call (212) 353-8280, extension 212.

Sincerely, ATC Associates, Inc

James R. Cohn, CIH, CSP Regional Manager Industrial Hygiene Division

Attachment

CITY_21MC100_003068142

NYC-WTC_000203432

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000203432Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →