TEM Asbestos (air) Count Sheet
Client Name; NYC BOE Volume (liters): 184Q
Lab Group #: €953 Filter Type / Filter Area: MCE 385 mm^
Lab Sample #: 5 Grid Opening Size: 0.01124
Client Sample #: 5 Area Examined: 0.04496 mm-
GRID BOX:
GRID ID:
w Magnification:
Accelerating Voltage:
20,000
TOO KeV
# Grid Openings: 4 Analysis Date: 3/6/02 ■
Analysis Performed By:
ROMAN PEYSAKHOV
GO, Structure Structure Type Length ID of Structure N or 9- EDS
No (Nonadb
F B C M ^=05 p T Chrys Amphibole ,Nonasb Ambig/ND
~ - No Coord <5|j I Elements)
!'
. i
t
Struct = > 0.5(1 >5:1 Aspect Ratio Grid acceptance;;
■/- Positive diffraction pattern properties conforming to <50% undissoived filter, overlapped or folded Totals
laoprclory identification criteria observed <10% particulate coverage >50% coverage ate
least 20 unfolded or overlapped grid squares <5% F B C M i
aF EDS speefrum conforming to laboratory I holes or opaque areas
identification criteria observed Chrysotile
AMPHIBOLES Amphibole
F = Single Fiber ; Amosite
B = Bundle (<3 fibers <1 fiber diameter apart Crocidolite Ambiguous
C -Custer (>3 intersections) Anthophyllite Non-Asbestos
Tremolite
M = Matrix > Non-Identified
Actinolite
NSD = No Structures Detected
CITY_21MC100_003269163
NYC-WTC_000201813
OCR can misread numbers and units. Confirm readings against the page image before using them.
NYC-WTC_000201813Source: NYC Law Department, mirrored locally
Laboratory count sheet documenting transmission electron microscopy analysis of an air sample collected from a NYC Board of Education site on May 4, 2002.