NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State SLAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP.Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/19/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Ensrgy-Dispersive X-RAY Spectroscopy (EDS) Method; AHERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1967

Sample Identificaticn Analysis Parameters

Froject/Site; P 130M, 143 Baxter St., KY,.NY TEM Sample No.: 5725 - 61674 Throughout the School Fuildinq Date Received: 10-18/01 Grid Openings Analyzed:_ 4

Project Semple No. : 19 Average Grid Opening: 105.00 urn

Air Volume :^^^072Aters Dotal Area Analyzed: C.045C mm2

Filter Ti'P-e: MCE 25 mm diam. , Pore Site: 0.45 urn Analytical Sensitivity: 22.2 s/nim2 Effective Area: 365 mm2 C.004E

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct, Filter Air Fibers Bundles Clusters Struct. Struct Strvct/nm2 nom/mS

Chrysotile Asbestos 0 0 0 0 0 0 0.0 0 .OODO 0

Amphibcle Asbestos 0 0 0 0 0 0 0 .0 0 .OODO 0

Ambiguous 0 D 0 0 0 0 0.c 0.0000 0

Total asbestos (includes ambiguous structures) 0 0 0.0 0.OODO 0 Non-A.sbestos 0 0 0 0 0 0 0 .0 0.0000 N/A No Identification 0 0 0 0 0 0 0 . 0 0.0000 N/A

Totals (All structures). 0 0 G.0 0 . OODO N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED); None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TSM method. This laboratory is in compliance with the quality specified fox" the method.

Analyzed by; Report Reviewed by:

Michael A . Gorycki, Ph. D Michael A Gorvcki, Ph.D. Director' of Electron Microscopy

CITY_21MC100_011274423

NYC-WTC_000200216

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000200216Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →