SEP-lS-20eil 10:54 USEPft-RESP. a PREU. BR. 321 4425 P.02/06

EPA Region 2 World Trade Center Emergency Response Activities to Date September 18, 2001

Since the day' of tire World Trade Center disaster, EPA, Emergency Response personnel have worked closely with State and local officials as well as other federal agencies to ensure the safety of rescue workers and surrounding population. EPA has assisted numerous financial firms in gaining access to their buildings and returning to operation.

The activities include: • Coutinuous air moaitoring: EPA has set up ten continuous air monitors in and around “ground zero,“ and is testing samples for the presence of asbestos, VOCs, lead and dioxin. The majority of sample results thus far indicate that asbestos levels arc below levels of concern. The highest levels carnc from a monitor located one-half block from ground zero, demoustrafing the need for rescuers to wear appropriate protective gear. We are awaiting other results.

Outdoor air sampling: Before establishing the continuous air .-uomtoring stations, EPA took daily air samples from a number of locations in lower Manhattan, as well as in western Brooklyn and Liberty State Park in New Jersey. 50 air samples were taken, a vast majority again showing levels of asbestos and other chemicals below EPA’s threshold of concern. In fact, in most cases, asbestos was not detected.

Indoor air sampling: EPA took 13 samples of mdoor air in two federal buildings last week, and again all samples showed asbestos levels that were well below levels of concern. These buildings are likely to be good indicators of asbestos levels in sound buildings in the area of tire disaster. EPA also reviewed data from an e.nvironmental company hired by titc New York Stock Exchange to inspect its building prior to the reopening on Monday, Sept. 17. Data from die Stock Exchange also showed no levels of concern.

Dust Sampling: EPA has taken 62 samples of dust m and around ground zero, including in the financial district. Most of these samples were below EP.A’s definition of asbestos containing material (1% asbestos). Where samples were shown to have greater than 1% asbestos - numbers ranged from 1.1 to 4.5% - EPA has vacuumed up the dust using special trucks and has re-samp I cd.

Vacuum Trucks; EPA has been operating 10 SUPERVAC HEPA vacuum trucks to .help the city cleanup the streets in the financial district, clean lobbies of federal buildings, and to assist where needed.

Drinking Water Sampling: EPA and the city split samples taken from 13 routine dnnlcng water sampling points in water mains in lower manhattan. Most of the analysis is not yet completed on these samples, but there were no detectable levels of asbestos.

Hudson River Sampling: EPA took a sample al the site of a storm drain near '‘ground zero” during a rain storm to determine the level of contaminants in water running off the site into the Hudson River. Results are expected this week.

TAG.A Unit: EPA is using its sophisticated mobile air monitoring unit to take samples of air and test for air toxics. None of the six samples taken indicated levels of concern.

Wastewater Treatment Plant: EPA took several samples from the Newtown Creek Sewage Treatment Plant, which is the recipient of storm water from lower Manhattan. Results are expected later this week.

X

CITY_21MC100_006842943

NYC-WTC_000195944

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000195944Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000143952 · Box DEP Box 07

Joint announcement of a comprehensive plan by the EPA and city partners to address indoor air quality concerns in residential units south of Canal Street.

Similar indexed content

Compare copies and versions →