300 gg/m^.

Fifth Floor Hallway - The fifth floor hallway is an area with plywood floors and walls made of sheet rock covered with wallpaper glue. The ceiling is also made of sheet rock, and is painted.

Cleaning Method - This area was cleaned twice using Test 4 A and Test 4B. Test 4 A used an industrial HEPA-filtered vacuum and an AFD, while Test 4B consisted of a soap and water wet w wipe of only the ceiling.

Cleaning Results - This unit met the clearance criteria listed in Table 1.0 for each compound after «r being cleaned twice. «r «r Asbestos Before Cleaning Samples - There were no samples collected before cleaning.

Post P‘ Cleaning Samples - Two air samples were collected. The air samples were analyzed using PCM. The PCM results were below the secondary numeric criterion of 0.01 flee. The samples could not be analyzed for PCMe, due to overloading of particulate matter on the filters.

Post 2^ Cleaning Samples - Two air samples were collected. The air samples were analyzed using TEM AHERA, and PCMe. The samples could not be analyzed for PCM, due to overloading of particulate matter on the filters The TEM AHERA results were below the secondary numeric criterion of 0.022 S/cc, with the samples being below the detection limit. Similarly, the PCMe results were below the primary clearance criterion of 0.0009 S/cc with the samples likewise below the detection limit. 4 4 Dioxin Before Cleaning Samples - There were no samples collected before cleaning. <4 Post P‘ Cleaning Samples - There were no post-first cleaning samples collected.

Post 2”‘' Cleaning Samples - There were no post-second cleaning samples collected. 4 Gypsum Before Cleaning Samples - There were no samples collected before cleaning.

Post P‘ Cleaning Samples - One air sample was collected after the first cleaning. Gypsum was not detected. Since gypsum was below the detection for the sample collected, no additional gypsum samples were collected.

Lead Before Cleaning Samples - There were no samples collected before cleaning.

Post P‘ Cleaning Samples - One air sample was collected after the first cleaning. The air sample was below the primary clearance criterion of 1.0 pg/m^ Since the primary

79

CITY_21MC100_011105309

NYC-WTC_000195275

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000195275Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →