NYC 9/11 Public Portal Document

Calcite Before Cleaning Samples - There were no samples collected before cleaning.

Post P‘ Cleaning Samples - Two air samples were collected after the first cleaning. Both were below the detection limit.

Cristobalite Before Cleaning Samples - There were no samples collected before cleaning.

Post P‘ Cleaning Samples - There were two air samples collected after the first cleaning. Both were below the detection limit.

Tridymite Before Cleaning Samples - There were no samples collected before cleaning.

Post P' Cleaning Samples - Two air samples were collected after the first cleaning. Both were below the detection limit.

MMVF Before Cleaning Samples - There were no samples collected before cleaning.

Post P‘ Cleaning Samples - Two air samples were collected after the first cleaning. The results indicate that MMVF was present in both samples; however, the concentrations were below the primary clearance criterion of 10 S/L. Because the air samples were below the primary clearance criterion, no additional samples were collected for MMVF.

PAH Before Cleaning Samples - There were no samples collected before cleaning.

Post P' Cleaning Samples - There were no samples collected after cleaning.

Unit 4A - This unit is located on the fourth floor. It is a 1,368 sq. ft. open loft facing Cedar Street. No windows were blown in and there was minimal dust accumulation in the dwelling with the exception of the baseboard heating units, which contained visible dust. The unit has hardwood floors. All of the tenant’s personal items were removed prior to the cleanup.

Cleaning Method - This unit was cleaned using Test 2 A; a Craftsman® shop vacuum and Eureka® upright vacuum with a HEPA filter for vacuuming the floors and other surfaces. There were no AFDs used during the cleaning process. In addition, all horizontal surfaces were wet wiped. This cleaning method was used for each cleaning event.

Cleaning Results - This unit met the clearance criteria listed in Table 1.0 for each compound after being cleaned twice.

Asbestos Before Cleaning Samples - Three micro vacuum and four wipe samples were collected 58

CITY_21MC100_011105288

NYC-WTC_000195254

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000195254Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →