5.8 Air Disturbance
The asbestos air samples were collected using two types of air disturbance prior to sampling.
Either an aggressive technique, using a leaf blower and oscillating fans to disturb the air, or a
modified-aggressive technique, using only oscillating fans to disturb the air was used. In several
instances both methods were used in the same apartment to evaluate if there was a difference in
the analytical results. Both the aggressive and modified-aggressive techniques are expected to
create air disturbance over an eight-hour sampling period that represents either a worst-case or
high-end (respectively) air movement in an indoor environment, which would provide a
conservative estimate of the airborne asbestos concentration.
ii
I Table
Comparison of Airborne Asbestos Samples Collected Using Modified-Aggressive and
Aggressive Air Disturbance Methods’’
w
resave Air JMsiurbenee Aggressive Air fiisiurltattce
liMi SamplelP | Result I Units
9094-A-2A-25 0.0004 S>5pycc 9094-A-2A-28 < 0.0005 S>5p/cc
2A 9O94-A-2A-2O 0.0004 s> 5m/cc 9094-A-2A-29 < 0,0005 S>5m/cc
9094-A-2A-27 0,0004 S> 5p/cc 9094-A-2 A-30 < 0,0005 S> 5p/cc
iS
9094-A--3B-39 < 0,0005 S> 5p/cc
3B 9094-A-3B-40 < 0 0005 S> 5p/cc
9Q94-A-3B-41 <0.0005 S>5m?cc
■ar ;i:9094-A-3€^233 < 0,0005 S> 5p/cc 9O94A-3C-35 < 0.0005 S> 5p/cc
3C: 9094-A-3C-33 < 0.0005 S> 5n/cc 9O94-A-3C-36 <0,0005 S>5p/{y
9094-A-3C-34 < 0,0005 S> 5p/cc 9094-A-3C-37 < 0.0005 S> 5p/cc
3» 90Q4-A-3D-23 < 0.0005 S> 5p/cc 9e-94-A-3P-33 < 0.0005 S>5m/cC
9094-A-3D-24 <0.0005 S>5p/cc 9094-A-3D-34 <0.0005 S>5p/cc
9O94-A-5C-33 0.0016 $>5p/cc
9094-A-5C-32 < 0,004 S> Sp/cc 9O94-A-5C-34 0.0015 S>5p/cc
4
* Number Below
Detection Limit 9/13
«
Percent Below
Detection Limit 69.2% 80.0%
Average 8.00045 0.00671
In apartments where both methods were used, the modified-aggressive technique was used first
and air samples were collected. Several days later, the aggressive technique was used and
additional air samples were collected with no cleaning events occurring between sampling events.
w
^’Samples below the detection limit were assigned a value equal to the detection limit. Comparison of
asbestos air samples that were collected using modified-aggressive and aggressive air disturbance. The samples
collected using modified-aggressive air disturbance (i.e., box fans) were collected several days prior to the samples
collected using aggressive air disturbance (i.e., leaf blower and box fans). The comparison does not show any
trends, as the percentage of samples below the detection limit was higher for the aggressive air disturbance while
the average asbestos concentration was nominally lower for the modified-aggressive air disturbance.