TEM Asbestos air sample results, NYC BOE, June 2002
Machine-extracted title · confidence 95%
Laboratory report documenting transmission electron microscopy analysis of an air sample collected from a New York City Board of Education site in June 2002.
GO. structure Structure Type Length ID of Structure N or ■/ EDS
No >=05 p Amphibole (Nonadb
F B C M >=5|j Chrys Nonasb Ambig/ND
No Coord <5p Elements)
i=
Struct = > 0.5p > 5:l Aspect Ratio Grid acceptance:
Positive diffraction pattern properties conforming to <50% undissolved filter, overlapped or folded Totals
laboratory identification criteria observed <10% particulate coverage >50% coverage ate
least 20 unfolded or overlapped grid squares <5% F B C M
V= EDS spectrum conforming to laboratory holes or opaque areas
identification criteria observed Chrysotile
AMPHIBOLES : Amphibole
F = Single Fiber ' Amosite i
B = Bundle (<3 fibers <1 fiber diameter apart ! Crocidolite Ambiguous
C = Cluster (>3 Intersections) j Anthophyllite Non-Asbestos
j Tremolite
M = Matrix Non-ldentified
I Actinolite
NSD = No Structures Detected
CITY_21MC100_003091868
NYC-WTC_000191879
OCR can misread numbers and units. Confirm readings against the page image before using them.
NYC-WTC_000191879Source: NYC Law Department, mirrored locally
Laboratory report documenting transmission electron microscopy analysis of an air sample collected from a New York City Board of Education site in June 2002.