i.
Best Management Practices (for Recyclers in NJ) for Handling WTC Steel Which May Contain Asbestos in Spray-on Fireproofing (S.OF)
NY DEC and NYC EPA have their own set of guidelines that must be adhered to by successful bidders in NY State and/or NY City. Sampling of SOF Adhering to WTC Steel. Representative samples must be collected on a weekly basis from each recycler who has received WTC scrap in the. previous week. Sufficient samples should be collected each week such that a minimum of 5-10% of new SOF arriving at each facility is sampled. No more than one sample should be taken from each steel member tested. Samples should be analyzed using the method cited in 40 CFR 763 Appendix E, Subpart E, Section 1, as is currently being used.
EPA and NJDEP/NJDOH reserve the right to oversee sampling operations or to conduct simultaneous sampling to ensure representative sampling. Sample results must be transmitted to EPA and NJDEP electronically within 24 hours of receipt in a spreadsheet format provided by EPA.
Personal Air Monitoring of Workers. Samples are to be collected and analyzed on a weekly basis from at least 10% of workers. Samples sould be taken from workers who are scheduled to work at least 6 hours with WTC scrap on the day of sampling. Whenever possible, samples are to be taken from workers with the greatest number of hours of exposure on the sampling day. In very dusty conditions, sufficient cassettes should be used to get a reasonable estimate of short-term as well as 8 hour exposure. Samples are to be collected and analyzed in accordance with 29CFR 1910, Occupational Exposure to Asbestos and are to be analyzed using Phase Contrast Microscopy (PCM). Sample results must be transmitted reported to EPA and NJDEP within 24 hours of receipt using the spreadsheet provided by EPA.
Air Monitoring in Residential Areas within 1000 feet of Recycling Operations Air samples must be collected once a week from residential areas within 1000 feet of recycling operations. Samples should be taken using 40 CFR 763 Appendix A to Subpart E-- Interim Transmission Electron Microscopy Analytical Methods. Results must be reported to EPA and NJDEP within 24 hours of receipt using the spreadsheet provided by EPA.
AMEC STEEL BID ADDENDUM 4 4 12/G5/01
CITY_21MC100_010307815
NYC-WTC_000188107
OCR can misread numbers and units. Confirm readings against the page image before using them.
Related records
Browse subjects →Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
Same-box records
4 shared non-person entities · similarity 0.929
machine-extracted · confidence unavailable · Check page ↗Filed elsewhere
NYC-WTC_000146129
Correspondence from NYC Corporation Counsel providing comments on excerpts of a draft EPA evaluation report regarding the WTC response.
3 shared non-person entities · similarity 0.921
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000149432
DEP asbestos project notification form and inspection report dated December 12, 2002.
3 shared non-person entities · similarity 0.919
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000149936
Joint OSHA and Bechtel crane inspection report analyzing safety conditions at the World Trade Center site.
3 shared non-person entities · similarity 0.919
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000094912
Invoice detailing billing for bulk and air sample analysis results including PLM, PCM, and TEM testing at 44 Wall Street.
3 shared non-person entities · 1 shared topics · similarity 0.918
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000128550
Asbestos inspection report notification form submitted to NYC DEP for 102-104 Greenwich Street.
3 shared non-person entities · similarity 0.917
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000098612
Contract specifications outlining site decontamination and asbestos disposal procedures for 110 Church Street.
3 shared non-person entities · similarity 0.917
machine-extracted · confidence unavailable · Check page ↗3 shared non-person entities · similarity 0.917
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000115124
Fax cover sheet from DEP Enforcement dated September 5, 2002, transmitting 13 pages regarding WTC debris.
3 shared non-person entities · similarity 0.916
machine-extracted · confidence unavailable · Check page ↗2 shared non-person entities · similarity 0.916
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000116133
List of site identifiers including block, lot, and BIN numbers associated with the 22 Thames Street location.
3 shared non-person entities · similarity 0.915
machine-extracted · confidence unavailable · Check page ↗More like this page
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.945 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000150163
Internal memo draft addressed to the Commissioner regarding environmental compliance actions and correspondence drafts dated October 15, 2001.
Similarity score 0.945 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000162890
Technical discussion regarding discrepancies in NIOSH method flow rates and requirements for large sample volumes at 114 Liberty Street.
Similarity score 0.944 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000102605
Scope of work document dated February 2003 detailing a mandatory pre-bid meeting and requirements for asbestos abatement contractor cleaning at 114 Liberty Street.
Similarity score 0.944 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Others also read
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
Similar indexed content
Similar indexed content
NYC-WTC_000146129
Correspondence from NYC Corporation Counsel providing comments on excerpts of a draft EPA evaluation report regarding the WTC response.
Similar indexed content
DEP asbestos project notification form and inspection report dated December 12, 2002.
Similar indexed content
Joint OSHA and Bechtel crane inspection report analyzing safety conditions at the World Trade Center site.
Similar indexed content