TEM Asbestos (air) Count Sheet
Client Name: NYC BOE Volume niters): 1928
Lab Group #: 7092 Filter Type / Filter Area: MCE 385 mm-
Lab Sample #: 9 Grid Opening Size: 0.01124
Client Sample #: 11 Area Examined: 0.04496 mm-
GRID BOX: Magnification: 20,000
GRID ID: Accelerating Voltage: 100 KeV
# Grid Openings: 4 Analysis Date: 3/16/02
Analysis Performed By:
MARK PEYSAKHOV
GO. Structure Structure Type Length ID of Structure N or v EDS
(Nonadb
No F B C M >=05 u :>=5(J Chrys Amphibole Nonasb Ambig/ND
( No 5 Coord <5(j
Elements)
I
Struct = > 0.5p _> 5:1 Aspect Ratio Grid acceptance:
^/= Positive diffraction pattern properties conforming to <50% undissolved filter, overlapped or folded Totals
laboratory identification criteria observed <10% particulate coverage >50% coverage ate
least 20 unfolded or overlapped grid squares <5% F B C M >5p
■J= EDS spectrum conforming to laboratory holes or opaque areas
identification criteria observed Chrysotile
AMPHIBOLES Amphibole
F = Single Fiber Amosite
B = Bundle (<3 fibers <1 fiber diameter apart Crocidolite Ambiguous
C = Cluster (>3 Intersections) i Anthophyllite Non-Asbestos
T remolite
M = Matrix Actinolite Non-Identified
NSD = No Structures Detected
CONFIDENTIAL, CITY_21MC100_003468552