NYC 9/11 Public Portal Document
TEM Asbestos (air) Count Sheet
Client Name: NYC BOE Volume (liters): 1936
Lab Group #: 7058 Filter Type / Filter Area: MCE 385 mm"
Lab Sample #: 4 Grid Opening Size: 0.01124
Client Sample #: 04 Area Examined: 0.04496 mm"
GRID BOX: Magnification: 20,000
GRID ID: Accelerating Voltage: 100 KeV
# Grid Openings: 4 Analysis Date: 3/13/02
Analysis Performed By:
ROMAN PEYSAKHOV
GO. Structure Structure Type Length ID of Structure NorV EDS
No Amphibole Nonasb (Nonadb
F B C M >=5p Chrys Ambig/ND
No Coord <5u Elements)
zz we
(/
!
T
Struct = > 0.5p -> 5:1 Aspect Ratio Grid acceptance:
Positive diffraction pattern properties conforming to <50% undissolved filter, overlapped or folded Totals
laboratory identification criteria observed <10% particulate coverage >50% coverage ate
least 20 unfolded or overlapped grid squares <5% F B C M i >5p
V= EDS spectrum conforming to laboratory holes or opaque areas
identification criteria observed Chrysotile
AMPHIBOLES Amphibole
F = Single Fiber Amosite
B = Bundle (<3 fibers <1 fiber diameter apart Crocidolite Ambiguous
C = Cluster (>3 Intersections) Anthophyllite Non-Asbestos
T remolite
M = Matrix Npn-Identified
Actinolite
NSD = No Structures Detected
CONFIDENTIAL, CITY_21MC100_003468502
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000181447
OCR can misread numbers and units. Confirm readings against the page image before using them.