NYC 9/11 Public Portal Document
TEM Asbestos (air) Count Sheet
Client Name: NYC BOE Volume (liters): 1920
Lab Group #: 6910 Filter Type / Filter Area: MCE 383 mm’
Lab Sample #: 10 Grid Opening Size: 0.01124
Client Sample #: 10 Area Examined: 0.04496 mm'
GRID BOX: Magnification: 20,000
GRID IP: Accelerating Voltage: 100 KeV
# Grid Openings: 4 Analysis Date: 3/3/02
Analysis Performed By:
MARK PEYSAKHOV
GO. Structure Structure Type Length ID of Structure N or T EDS :
(Nonadb
No F B C M >=05 p >=5p Chrys Amphibole Nonasb Ambig/ND
No Coord <5p Elements)
I
Struct = > 0 5p > 5:1 Aspect Ratio Grid acceptance:
Positive diffraction pattern prooerties conforming to
<50% undissolved filter, overlapped or folded Totals
<10% particulate coverage >50% coverage ate
laboratory identification criteria observed
least 20 unfolded or overlapped grid squares <5% F B C M i >5m
V= EDS spectrum conforming to laboratory holes or opaoue areas
identification criteria observed Chrysotile
AMPHIBOLES Amphibole
F = Single Fiber Amosite
B = Bundle (<3 fibers <1 fiber diameter apart Crocidolite
Ambiguous
C = Cluster (>3 Intersections) Anthophyllite Non-Asbestos
T remolite
M = Matrix Non-Identified ‘
Actinolite
NSD = No Structures Detected
CONFIDENTIAL, CITY_21MC100_003468286
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000181298