NYC 9/11 Public Portal Document
TEM Asbestos (air) Count Sheet
Client Name: NYC BOE Volume (liters): 1984
Cab Group #: 6573 Filter Type / Filter Area: MCE 385 mm-
Lab Sample #: 3 Grid Opening Size: 0.01124
Client Sample #: 3 Area Examined: 0.04496 mrn-
GRID BOX: Magnification: 20,000
GRID ID: Accelerating Voltage: too KeV
# Grid Openings: 4 Analysis Date: 2/6/02
Analysis Performed By:
MARK PEYSAKHOV
GO, I Structure Structure Type Length ID of structure N or 7 EDS
(Nonadb ,
No F B C M >=05 p : Chrys Amphibole Nonasb Ambig/ND
No Coord <5u Elements)
Struct = > 0.5|i >5:1 Aspect Ratio Grid acceptance:
7= Positive diffraction pattern properties conforming to <50% undissolved filter, overlapped or folded Totals
laboratory identification criteria observed <10% particulate coverage >50% coverage ate
least 20 unfolded or overlapped grid squares <5% F B C M >5u
7= EDS spectrum conforming to laboratory holes or opaque areas
identification criteria observed Clirysotile
AMPHIBOLES Amphibole
F = Single Fiber Amosite
B = Bundle (<3 fibers <1 fiber diameter apart Crocidolite
Ambiguous
C = Cluster (>3 Intersections) Anthophyllite Non-Asbestos
Tremolite
M = Matrix
Actinolite Non-Identified
NSD = No Structures Detected
CONFIDENTIAL, CITY_21MC100_003467750
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000180933