NYC 9/11 Public Portal Document
TEM Asbestos (air) Count Sheet
Client Name: NYC BOE Volume (liters): 1920
Lab Group #: 6562 Filter Type / Filter Area: MCE 385 mm-
Lab Sample #: 8 Grid Opening Size: 0.01124
Client Sample #: 08 Area Examined: 0.04496 mm’
GRID BOX: 713 Magnification: 20,000
GRID ID: Accelerating Voltage: 100 KeV
# Grid Openings: 4 Analysis Date: 2/5/02
Analysis Performed By:
ROMAN PEYSAKHOV
GO. Structure Structure Type Length ID of Structure N or N EDS
No (Nonadb
F B C M >=05 p : =5p Chrys Amphibole Norasb Ambig/ND
No Coord <5p Elements)
ip I
I 2-V^ 1/
>70^ V__
ft
!
Struct = > 0.5p >5:1 Aspect Ratio Grid acceptance:
Positive diffraction pattern properties conforming to <50% undissolved filter, overlapped or folded Totals
laboratory identification criteria observed <10% particulate coverage >50% coverage ate
EDS spectrum conforming to laboratory
least 20 unfolded or overlapped grid squares <5% T B C M >5u
holes or opaque areas
identification criteria observed Chrysotile
AMPHIBOLES Amphibole
F = Single Fiber Amosite
B = Bundle (<3 fibers <1 fiber diameter apart Crocidolite Ambiguous
C = Cluster (>3 Intersections) Anthophyllite Non-Asbestos
Tremolite
M = Matrix Non-Identified
Actinolite
NSD = No Structures Detected
CONFIDENTIAL, CITY_21MC100_003467734
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000180923
OCR can misread numbers and units. Confirm readings against the page image before using them.