NYC 9/11 Public Portal Document
TEM Asbestos (air) Count Sheet
Client Name: NYC BOE Volume (liters): 1928
Lab Group #: 6081 Filter Type / Filter Area: MCE 385 mtn^
Lab Sample #: 10 Grid Opening Size: 0.01124
Client Sample #: 12 Area Examined: 0.04496 mm*
GRID BOX: Magnification: 20,000
GRID ID: Accelerating Voltage: 100 KeV
# Grid Openings: 4 Analysis Date: 12/12/01
Analysis Performed By:
MARK PEYSAKHOV
GO. Structure Structure Type Length ID of Structure NorV EDS
No (Nonadb
F B C M >=5|J Chrys Amphibole Nonasb Amoig/ND
No Coord <5p Elements)
T-
Struct = > 0.5n >5:1 Aspect Ratio Grid acceptance:
A- Positive diffraction pattern properties conforming to <50% undissolved lilter, overiapped or folded Totals
laboratory identification criteria observed <10% particulate coverage >50% coverage ate
least 20 unfolded or overlapped grid squares <5% F B C M >5p
A- EDS spectrum conforming to laboratory holes or opaque areas
identification criteria observed Chrysotile
AMPHIBOLES Amphibole
F = Single Fiber Amosite
B = Bundle (<3 libers <1 fiber diameter apart Crocidolite Ambiguous
C = Cluster (>3 Intersections) Anthophyllite Non-Asbestos
T remolite
M = Matrix Non-Identified
Actinolite
NSD = No Structures Detected
CONFIDENTIAL, CITY_21MC100_003467428
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000180716
OCR can misread numbers and units. Confirm readings against the page image before using them.